I do not think the power pin is the problem. The problem is how your netlist corresponds to the pins in your component. I usually use the same pin numbers for all pins that are the same (multiple pins) on the component. Use only one pin for them in the schematic/netlist. Check that and also provide the output of the DRC test. Martin
On Wed, May 27, 2009 at 11:48 AM , Philip Axer wrote: > Hi, > first off, I'm fairly new to kicad but I couldn't find any useful > information for my problem out there: > So, I created a new component (voltage regulator) which has 3 power > out pins (all of the same potential). Now I'm trying to use my new > component in an actual design, thus I connect all power out pins of > the regulator to the same power net. The issue that the DRC throws > some errors because only one pin is allowed to drive a power net. How > to solve this issue? > > Philip > > -- > Dipl.-Ing. Philip Axer > Institut für Datentechnik und Kommunikationsnetze > Hans-Sommer-Straße 66 38106 Braunschweig > Tel +49 (531) 391 9662 Fax +49 (531) 391 3750