Before you attempt any track operations select Edit...Cleanup Tracks and 
Vias.   Deselect everything except Merge segments, and then hit the 
Clean pcb button.

Regards,

Robert.


On 09/04/2010 10:23, Anders O wrote:
> The suggested approach works very well, though the track is now
> devided into two tracks, which disables "drag segment, keep slope".
> Joining two tracks is a feature I miss. Sometimes, it's simply easier
> to delete and retrace :(
>
>
>
>
> ________________________________ From:
> Robert<birmingham_spi...@gmx.net> To: kicad-users@yahoogroups.com
> Sent: Fri, April 9, 2010 10:56:07 AM Subject: Re: [kicad-users] How
> to restore/set Net Name to Tracks.
>
>
> Have you tried "Rebuild Board Connectivity" from the netlist import
> dialog? From memory you just turn off the DRC so you can connect the
> orphan track to the appropriate net, and then you hit this button.
> Then you can turn on the DRC again and carry on working as normal.
>
> Regards,
>
> Robert.
>
> On 08/04/2010 18:11, Cat C wrote:
>>
>> I don't know if I'm the only one, but quite often some tracks will
>> loose their net name so I can't attach them to the desired pad.
>>
>> How can I restore, or set (if there never was) the net of a track,
>> please?
>>
>> Thanks,
>>
>> Cat
>
>
>
>
>
>
>
>
> No virus found in this incoming message. Checked by AVG -
> www.avg.com Version: 9.0.801 / Virus Database: 271.1.1/2799 - Release
> Date: 04/08/10 19:32:00
>
No virus found in this outgoing message.
Checked by AVG - www.avg.com 
Version: 9.0.801 / Virus Database: 271.1.1/2799 - Release Date: 04/08/10 
19:32:00

Reply via email to