Hi John,
For your last subject, there is no auto-connect between pins of symbols (power 
symbols like others). The only connection is made by wires or named nets/busses.

Yves.

--- In [email protected], NeonJohn <j...@...> wrote:
>
> Thanks for the tip.  I finally punted and ran the annotation with the
> "reannotate everything".  That got the ERC working.  Now I'm chasing
> phantom errors.  In most cases, deleting the trace or more often, the
> ground symbol and re-placing it will make the error go away.  I've
> learned that if I drop a ground symbol right on the pin of a component
> with no connecting wire, it'll get flagged as a non-connect.  Real PITA.
>  I have a LOT of those to fix.
> 
> John
> 
> 
> Stephen Eaton wrote:
> > G'day John,
> > 
> >  
> > 
> > I myself am fairly new to kicad as well, but have just finished a project as
> > a means to better learn kicad.
> > 
> >  
> > 
> > With my experiences I found that ERC won't fully run until it sees all
> > components are annotated.
> > 
> >  
> > 
> > Have you run the annotation tool to see if it picks up the unannoted
> > component?
> > 
> >  
> > 
> > Stephen...
> > 
> >  
> > 
> >  
> > 
> >  
> > 
> > From: [email protected] [mailto:[email protected]] On
> > Behalf Of NeonJohn
> > Sent: Tuesday, 27 April 2010 12:02 PM
> > To: [email protected]
> > Subject: [kicad-users] Schematic ERC
> > 
> >  
> > 
> >   
> > 
> > I'm using the latest official release under Ubuntu (Build: (20100406
> > SVN-R2509)-final) After abandoning KiCAD a couple of releases ago as
> > not ready for prime time, I'm back to try again. I've entered a fairly
> > complex design involving an FPGA, a processor and some analog stuff.
> > Being fairly new to this and considering the complexity, I can't believe
> > that I made no mistakes. that's what the ERC checker is saying. When I
> > bring it up and click "Test ERC", I get the following message:
> > 
> > item not annotated: 0.1uF?
> > Annotation required!
> > 
> > But nothing in the marker window. I've checked every single bypass
> > capacitor both manually and by searching for the value. They're all
> > annotated.
> > 
> > So. Is ERC broken in this release or was I really that good? :-) And
> > what's with the annotation message?
> > 
> > Thanks,
> > John
> > 
> 
> -- 
> John DeArmond
> Tellico Plains, Occupied TN
> http://www.neon-john.com    <-- email from here
> http://www.johndearmond.com <-- Best damned Blog on the net
> PGP key: wwwkeys.pgp.net: BCB68D77
>