Hello Anders.

> It works, but if I rewrite the net file from EESchema, it reverts back.
> What has happened? It is probably something silly I have done, but I cabnnot
> find out what?

Because the original mishap comes from the Symbols in EESchema. If the Pin in 
the Symbol are numbered with A, B, ....(They can actually get numbered 4 Letter 
Alpanumerical), then EESchema will also create Netlists with A, B, and so on. 
So You have to edid the symbol, not the netlist.

I did something silly too, when i created my EN60617 Library, with Diodes
and Transistors first. I named the Pins A and K, or B, C, E.......
Much work to chance it after i noticed my error.......

But i think, at some ICs, naming the Pins and Pads with a memnonical oriented 
Number would be nice. The problem is, that there are different Footprints with 
different numbering for the same symbol (Like MIC4422 wit 8pin Dil/SO and 5Pin 
Pentawatt). So it would be nice at CVpcb to have a tool for fiddling Symbol 
numbers to pad numbers. At moment, i created two different Symbols for the 
MIC4422, one with the 8 Pin numbering, and one with 5 Pin numbering.


With best regards: Bernd Wiebus alias dl1eic


-- 