Hi Jean Paul,
Check your cooling inlet size.........I got overheating on my first flight
-engine quit on base leg -flopped in and broke my prop.
No sign of overheating on ground run- ups.
I enlarged my inlet ports and fitted an adjustable airflow exit flap.
Worked for me. Sorry if you have passed this stage.
Good luck.....Mac