Zhao, Yunfeng wrote:
> Hi,
> We ran a testing against latest KVM to know its quality status.
> In the testing we tried to boot guests, test basic devices of guest, and
> install guests.
>   

Thanks for doing this -- it is enormously useful.

> Basic devices, Keybord,disk,VGA, and nic works well, but timer is NOT
> accurate while running some workload on guests.
>   

We found that using an hrtimer enabled host with CONFIG_HZ=1000 improves 
things.  However I don't think that it's as accurate as 7 seconds in 20 
minutes (that's better than 1% accuracy), so probably more work is 
needed in qemu to correct time drift.



-- 