On 02/23/2012 02:49 AM, Zhang, Yang Z wrote:
>> > 6) Setting the clock after 500 ms happens not on every set, but only when 
>> > moving
>> > out of divider reset (register A bits 5-7 moving from 110 or 111 to 010).  
>> > As far as
>> > I can read, SET prevents the registers from changing value, but keeps the 
>> > internal
>> > sub-second counters running.
> Do we really need this logic? It sounds like senseless. 

It doesn't seem hard to do, see my branch.