If at default-
any ringing co rings all stations,
if stations are used as co's
you get a loop
ring co1,
all stas ring
causing all connected cos to ring.

-larry




[EMAIL PROTECTED] wrote:

>I should probable know this .  I pulled a couple of old KX-TD1232's  off the 
>shelf to check them out 
>(Version P211D00712A).  I hooked up a couple analog ports to be co  lines.  
>When I dialed one of the extensions both would ring no matter which  co's I 
>used.  I could get on one line & dial the other & it would  work fine.  When I 
>unhooked the co's the analog lines would ring  separably.  Any suggestions.  
>Both cabinets did the same thing.
> 
>Thanks
> 
>Ken
> 
>
>
>
>**************************************See AOL's top rated recipes 
>(http://food.aol.com/top-rated-recipes?NCID=aoltop00030000000004)
>_________________________________________________________________
>KX-T Mailing list --- http://kxthelp.com/
>Subscription changes: http://kxthelp.com/mailman/listinfo/kxt
>
>  
>


_________________________________________________________________
KX-T Mailing list --- http://kxthelp.com/
Subscription changes: http://kxthelp.com/mailman/listinfo/kxt

Reply via email to