Are the telco trunks 1MB or PBX class of service? Have there been any facilities changes, like new poles, re-routed roads (which required telco cable movement) in the area?
If it is not the -616 doing the squeal, I'd suspect PBX-class lines with CO MFT units on each line. They will go nuts if the telco cable gets "longer" or gains a bridge tap somewhere along the way..... ----- Original Message ----- From: "Charles P" <[EMAIL PROTECTED]> To: "kxthelp" <[EMAIL PROTECTED]> Sent: Wednesday, October 03, 2001 11:28 PM Subject: KX-T: analog 616 squeal > Customer has an analog 616. They report that at least a couple of times each > day, incoming callers will hear a squeal then the phone disconnects and they > have to call back. The office personnel answer the call but only get the > hang up (they don't hear the squeal internally). > > It happens on any phone, and on any line, various times of day. Verizon > says it's not their problem. > > any clues on this one? > > Charles > > > > [EMAIL PROTECTED] > Global Communications > Tarrytown, NY > www.avtele.com > www.telephonesecurity.com > > > > ********************************************************* > * To unsubscribe, e-mail [EMAIL PROTECTED] * > * The KXT-Digest Home Page: http://kxthelp.com/ * > ********************************************************* > ********************************************************* * To unsubscribe, e-mail [EMAIL PROTECTED] * * The KXT-Digest Home Page: http://kxthelp.com/ * *********************************************************