No luck :), still fails on "address tracker" and "loop remover":

https://jenkins.opendaylight.org/releng/view/l2switch/job/l2switch-csit-1node-switch-only-carbon/154/
https://logs.opendaylight.org/releng/jenkins092/l2switch-csit-1node-switch-only-carbon/154/archives/log.html.gz

BR/Luis


> On Oct 14, 2016, at 2:26 PM, Luis Gomez <ece...@gmail.com> wrote:
> 
> OK Tomas, I will try your patch 
> https://git.opendaylight.org/gerrit/#/c/46390/ on 
> l2switch-csit-1node-switch-only-carbon and let you know.
> 
> 
>> On Oct 14, 2016, at 1:23 PM, Tomáš Slušný <tomas.slu...@pantheon.tech> wrote:
>> 
>> Also, 6710 was already merged only in master branch, but not yet in boron. 
>> It have cherry-pick ready here: 
>> https://git.opendaylight.org/gerrit/#/c/46761/, but until it is merged, I 
>> think it would be better to check for improvement in Jenkins test for Carbon 
>> here: 
>> https://jenkins.opendaylight.org/releng/view/l2switch/job/l2switch-csit-1node-switch-only-carbon/
>> Od: Tomáš Slušný <tomas.slu...@pantheon.tech>
>> Odoslané: 14. októbra 2016 22:13
>> Komu: Luis Gomez; Abhijit Kumbhare
>> Kópia: An Ho; openflowplugin-dev; OpenDayLight-L2switch-Dev
>> Predmet: Re: [openflowplugin-dev] [L2switch-dev] Blocker bug analysis
>> 
>> ​6710 was related to both cluster and single node, because even in single 
>> node scenario, we are registering to ClusterSingletonService, what had 
>> problems when we tried to re-register, when we do not fully closed previous 
>> registration (so, when we disconnected and reconnected too fast). Most part 
>> of this fix was done in bug 6710, but part of it had to be done also in 
>> openflowplugin side in this gerrit patch: 
>> https://git.opendaylight.org/gerrit/#/c/46390/​. So, Luis, is it possible to 
>> run failing l2switch test on that patch and see, if it solves anything, or 
>> not?
>> 
>> Od: Luis Gomez <ece...@gmail.com>
>> Odoslané: 14. októbra 2016 21:49
>> Komu: Abhijit Kumbhare
>> Kópia: An Ho; openflowplugin-dev; OpenDayLight-L2switch-Dev
>> Predmet: Re: [openflowplugin-dev] [L2switch-dev] Blocker bug analysis
>> 
>> Well I think if openflowplugin people cannot figure out where the issue is, 
>> the next would be to get some debug and further analysis from l2switch 
>> people explaining the application miss-behavior.
>> 
>> If there are no people available in l2switch to do this, we can lower the 
>> priority to major or critical.
>> 
>> BR/Luis
>> 
>> 
>>> On Oct 14, 2016, at 12:35 PM, Luis Gomez <ece...@gmail.com> wrote:
>>> 
>>> As far as I can tell nothing we have done so far has helped l2switch test, 
>>> it is still failing.
>>> 
>>> BR/Luis
>>> 
>>>> On Oct 14, 2016, at 9:53 AM, Abhijit Kumbhare <abhijitk...@gmail.com> 
>>>> wrote:
>>>> 
>>>> About the first one - https://bugs.opendaylight.org/show_bug.cgi?id=6575: 
>>>> 
>>>> Tomas has said in yesterday's meeting that this was dependent on 
>>>> https://bugs.opendaylight.org/show_bug.cgi?id=6710. And that it was fixed. 
>>>> Can we retest? Also a question for Tomas: 6710 is cluster related - while 
>>>> 6575 is not clear if it is cluster or single node. Are we sure 6575 is 
>>>> fixed?
>>>> 
>>>> The second one: https://bugs.opendaylight.org/show_bug.cgi?id=6917 - Shuva 
>>>> will respond about that some time.
>>>> 
>>>> 
>>>> 
>>>> On Thu, Oct 13, 2016 at 9:50 PM, Luis Gomez <ece...@gmail.com> wrote:
>>>> Hi all,
>>>> 
>>>> We are getting close to Boron SR1 so I think it makes sense to review the 
>>>> 2 blocking issues we have:
>>>> 
>>>> 
>>>> 1) https://bugs.opendaylight.org/show_bug.cgi?id=6575
>>>> 
>>>> Summary:
>>>> 
>>>> l2switch does not work well when mininet is disconnected and connected 
>>>> with no time in-between.
>>>> 
>>>> Description:
>>>> 
>>>> This is kind of old issue, since the He->Li migration the l2switch has 
>>>> experienced random issues in the system test:
>>>> 
>>>> https://jenkins.opendaylight.org/releng/view/l2switch/job/l2switch-csit-1node-switch-only-boron/
>>>> 
>>>> Same test passes fine in Beryllium as you can see below:
>>>> 
>>>> https://jenkins.opendaylight.org/releng/view/l2switch/job/l2switch-csit-1node-switch-only-beryllium/
>>>> 
>>>> The last discovery (just before Boron release) was that giving more time 
>>>> between stop mininet and start mininet made the suite pass.
>>>> 
>>>> Criticality:
>>>> 
>>>> Although this was a clear regression in l2switch test (Be->B), this bug 
>>>> was not initially marked as blocker because it was not trivial to 
>>>> reproduce (e.g. switch connection flap).
>>>> 
>>>> Risk of not fixing:
>>>> 
>>>> l2switch and other similar applications relying on ofplugin may not work 
>>>> well when switch connection flaps.
>>>> 
>>>> 
>>>> 2) https://bugs.opendaylight.org/show_bug.cgi?id=6917
>>>> 
>>>> Summary:
>>>> 
>>>> Flow matching function (operational flow reconciliation) is not stable.
>>>> 
>>>> Description:
>>>> 
>>>> I discovered this issue doing some random flow push test in my laptop 
>>>> using POSTMAN: adding and deleting the same flow few times produced an 
>>>> alien ID in the operational flow.
>>>> After that I have created a test that does exactly that: add flow, verify 
>>>> operational ID, delete flow, sleep 5s, repeat. With these simple steps the 
>>>> issue shows consistently for Boron (new test):
>>>> 
>>>> https://logs.opendaylight.org/releng/jenkins092/openflowplugin-csit-1node-flow-services-only-boron/758/archives/log.html.gz
>>>> 
>>>> But not in Beryllium:
>>>> 
>>>> https://logs.opendaylight.org/releng/jenkins092/openflowplugin-csit-1node-flow-services-only-beryllium/1854/archives/log.html.gz
>>>> 
>>>> Criticality:
>>>> 
>>>> Besides the test regression, I think there are applications in ODL relying 
>>>> on operational flow ID that would be negatively impacted by this bug.
>>>> 
>>>> Risk of not fixing:
>>>> 
>>>> OF applications relying on operational flow ID (e.g. to confirm flows) can 
>>>> sporadically fail.
>>>> 
>>>> 
>>>> _______________________________________________
>>>> L2switch-dev mailing list
>>>> L2switch-dev@lists.opendaylight.org
>>>> https://lists.opendaylight.org/mailman/listinfo/l2switch-dev
>>>> 
>>> 
>> 
>> TomášSlušný
>> Software Developer
>> 
>> Sídlo / Mlynské Nivy 56 / 821 05 Bratislava / Slovakia
>> R&D centrum / Janka Kráľa 9 /  974 01 Banská Bystrica / Slovakia
>> +421 911 083 902 / tomas.slu...@pantheon.tech
>> reception: +421 2 206 65 114 / www.pantheon.sk
>> 
>> 
>> TomášSlušný
>> Software Developer
>> 
>> Sídlo / Mlynské Nivy 56 / 821 05 Bratislava / Slovakia
>> R&D centrum / Janka Kráľa 9 /  974 01 Banská Bystrica / Slovakia
>> +421 911 083 902 / tomas.slu...@pantheon.tech
>> reception: +421 2 206 65 114 / www.pantheon.sk
>> 
>> 
> 

_______________________________________________
L2switch-dev mailing list
L2switch-dev@lists.opendaylight.org
https://lists.opendaylight.org/mailman/listinfo/l2switch-dev

Reply via email to