You wrote:
I have a subVI that needs an emergency stop. Once this stop is pressed, the VI should stop running. The subVI has several loops running sequentially. I want this " EmStop" button to take effect no matter at which execution point the VI is.
A long while ago I made a LV2 style global to do just that. It is called "Running Global" and is available for download from the very bottom of my LabVIEW page, http://www.SULLutions.com/LabVIEW.html. The VI description details its use.
--
Paul F. Sullivan----------------------------------------------------
SULLutions (781)769-6869
"when a single discipline is not enough"visit
----------------------------------------------------