This is just a shot-in-the-dark but try adding this to your labview.ini
file:

BldApp.RemovePolyVIsandTypedefs=False

Restart LV then rebuild your app.

Michael Aivaliotis

> -----Original Message-----
> From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]
> Behalf Of Vic Blosser
> Sent: Tuesday, February 03, 2004 3:26 PM
> To: Scott Hannahs; LabView (E-mail)
> Subject: RE: Labview 7 gotchas
>
>
> An example of one of the noted problems:
> Vi Function - Enter information for the devices to be tested.
>             - Display for entry of info and save to a file.
> For loop - it's setup to run for the number of devices to be tested.
>          - use loop counter (add one) to indicate which device
>          - fed to a sub vi and to spreadsheet build to send to a file.
>   Sub Vi Function - Display several fields to allow information
> be entered then continue.
>                   - set up - blank fields - display which device
>   Continuous loop - enter field information - press continue
> button - stop loop
>                   - pass info out of loop and out of the sub vi.
>          - information passed to build spreadsheet record to be
> saved to file.
>
> All this works fine in the development environment.  But after
> being compiled the displayed device numbers (for 6 devices) is:
> 1 1 2 3 4 5
> In the saved file it is:     1 2 3 4 5 6
>
> Very simple, it should work, but it doesn't.  I'm lost.  Worst
> case of magic I've ever seen.
>
> Vic,
>
>
>


Reply via email to