> >As I understand it a version of LabVIEW can always(?) open a VI written 
> >with an earlier LV version but the converse is not true.
> 
> That is only true for the development system. I think she said something
about built Vis
> which I would assume would mean VIs built into an executable. In that case
a runtime
> system can only open VIs saved in the same major and minor version as it
lacks the
> compiler support needed to recompile a lower version VI.
> 
> Rolf Kalbermatter
> 

That's because LabVIEW need a VI's wiring diagram to recompile it up to a
higher version, and building a VI into an executible removes it's diagram by
default.

Chris