Hello Martien,
Thank you for your inquiry regarding LabVIEW DataSocket. I understand
LabVIEW crashes when the third party OPC server generates an error.
The DataSocket Read.vi in LabVIEW 6.02 does not correctly handle
shutdown of the Lookout Protocol Driver (LPD) OPC Server. The
DataSocket Read VI (with wait for change =3D false) does not indicate
any errors if the Lookout Protocol Drivers OPC Server crashes or is
manually shutdown. Instead, it continues to read the last good value
from a previous call to DataSocket Read.vi. This causes LabVIEW to
crash. If you are using LabVIEW 6.02 one possible solution is use a
DataSocket Read.vi from LabVIEW 5.1 VI primitives. However, this
problem shouldn=92t occur on LabVIEW 7.0.

I hope these resources help. Let me know if I can further assist you.

Shea C.
Applications Engineering

Reply via email to