First you need to open a Vi-Reference to your Application. Then you should connect this with a property node. Use the property "panel". Add a second property node with the property "Controls[]". The "Controls[]" property node output is an array of references to the controls and indicators on the front panel. Connect this array to a for-loop. Inside the for-loop, put a third property node with the property "Indicator". This property node outputs =93True or False=94 depending on whether the referenced item is a =93control=94 or =93indicator=94. If the output is =93True=94, you can use a fourth propert= y node to make the indicator =93visible=94.
Russell G. Applications Engineer National Instruments