Hi,
You, the programmer, is in charge for what data type to use. Look in the functions
palette at *Advanced* and then *Data Manipulation* there you will find a blue icon
*variant*. In that palette, among other variant related things, you will find the
'Variant to data' function. You may wire in most any data type to convert to.
Hope this helps a bit...........
" I want to move to theory, everything works in theory"
Yours Sincerely,
Lennart Berlin
Advisory Engineer, Design & Production Support
Ericsson Microwave Systems AB
Sensors and Information Networks
SE-431 84 M�lndal
Sweden
Phone: +46 31 747 1696
Fax: +46 31 747 2830
Mobile: +46 70 987 1696
Email: [EMAIL PROTECTED]
http://www.ericsson.com/microwave/
Visitors address: Solhusgatan
412 76 Goteborg
-----Original Message-----
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] Behalf Of Kelly Bersch
Sent: den 7 maj 2004 17:29
To: [EMAIL PROTECTED]
Subject: Variant from COM interface
I'm controlling an external program using ActiveX and a com interface. One
of the properties returns a variant. I don't know what data type it will
translate to and I'm not sure how to find out. Can some one help me out?
I'm new to variants but have been using LabVIEW (6.02) for the last 3 years.
What am I not seeing?
Thanks
Kelly Bersch
Senior Technician
Anadigm
Telephone: 480-344-5262
Email: [EMAIL PROTECTED]
http://www.Anadigm.com
Anadigm - The Programmable Analog Company