I am trying to use continuous monitor to acquire data from my two
6052E DAQ cards.  I am using traditional daq vi's.  The DAQ cards are
running simultaneously in a seperate thread in TestStand while the
rest of my test is running.  The tests get lengthy (20 min) and the
file size of the data files also becomes large (there are 32 channels
monitored on one card and 4 on the other each monitored at a sample
rate of 10k).  I have set the write to file in a while loop, but
because of the large file size I have stripped off important signals
and written them to their own (smaller) file.  Problem is, now my
system is getting bogged down bc the write to file and data recording
is taking a while.  My scan backlog continues to get larger and the
tests in teststand begin to fail (I think this is bc the DMM driver is
not getting enough processor time to finish it's operations).  How
should I deal with monitoring so much data and keeping the file size
down?  This is obviously not the best way.