Larry,

All noise generation VIs (Analyze..Signal processing..signal
generation) have an optional terminal labeled "seed". Wire a constant
to it and you have what you need.

Look e.g. for "Uniform White noise.vi" or "Gaussian White Noise.vi",
etc.

(All LabVIEW versions excpet "base" should have these).