"Dan Press" <[EMAIL PROTECTED]> wrote:

>I create a separate application; let's call it the "YYY_Project Print
>Service.exe".  The application's job is just to sit there, but its INI
>file configured the VI Server to listen on a port other then the default
>3363.  See the app note -> 

Overall a very interesting and good idea to do!!

>Remember that built apps act like folders when you want to open a
>reference to a specific VI.  Just wire the path to your printing VI such
>as "C:\My App\YYY_Project Print Service.exe\Print Me.VI"

This is not necessary. In built applications LabVIEW (since at least ~ 6.0)
always searches the internal "LLB" for a VI with the last part of the path
first before even attempting to locate the VI at the absolute path if any
given. So for this one you can actually use a string with the VI name only
instead!

Rolf Kalbermatter
CIT Engineering Nederland BV    tel: +31 (070) 415 9190
Treubstraat 7H                  fax: +31 (070) 415 9191
2288 EG Rijswijk        http://www.citengineering.com
Netherlands             mailto:[EMAIL PROTECTED]
 