Hi,
1.09 was a full rewrite and big improvement on scanner profiler, but in very special cases gives results worst that anterior version. Could please send me the measurement of RGB? I mean the file generated by measurement tool. I will take a look Regards, Martí Maria The little cms project http://www.littlecms.com [EMAIL PROTECTED] ----- Original Message ----- From: "TME" <[EMAIL PROTECTED]> To: <[EMAIL PROTECTED]> Sent: Saturday, October 05, 2002 6:12 AM Subject: [Lcms-user] Problems with new version of LCMS - efficiency > Hello lcms-group, > > A year ago I created ICC for Superia 200 on Hewllet S20. I used CIECAM > and standard viewing conditions. I didn't select other options. The > profile was very good: > > Average dE :3.97 Standard deviation :3.82 > Peak : 22.35 Min : 0.28 > Average Target error: (99% confidence) 1.59 > Maximum error induced by target itself: 2.91 > > Now I used LSMC 1.09 and really can't get the same results. > Are there any changes in comp. to the 1.08 ver.? > Problems with measurement? > > -- > Jacek Zagaja, > "Good composition is the best [EMAIL PROTECTED] > way of seeing" ------------------------------------------------------- This sf.net email is sponsored by:ThinkGeek Welcome to geek heaven. http://thinkgeek.com/sf _______________________________________________ Lcms-user mailing list [EMAIL PROTECTED] https://lists.sourceforge.net/lists/listinfo/lcms-user