2009/11/23 Kai-Uwe Behrmann <k...@gmx.de>:
> Am 22.11.09, 14:29 +0100 schrieb Martin Weberg:
>> I figured out what was wrong. I need to set observer adaptation state
>> to 1 (fully adapted). Now Lab D50 values converts to sRGB pretty much
>> spot on according to both Photoshop and Bruce Lindbloom's calculator.
>
> Why manually convert to CIE*Lab (D65)?

Yes, no need doing that.

> The absolute colorimetric intent should be enough in one single
> colour transformation from CIE*lab (D50) to sRGB (D65).

Yes, true. I was trying to get adaptation working in absolute
colorimetric mode and tried transforming to Lab D65 before going to
sRGB D65.

Thanks for your input.

Martin Weberg

------------------------------------------------------------------------------