Hi, Older versions were incorrectly messing out the encoding. Now you got the right CIE L*a*b* value, which is (27.5, 0, 0) for V4 perceptual and (26.6, 0, 0) for relative colorimetric. Check any other conversion tool, Bruce Lindbloom's for example http://www.brucelindbloom.com/
Regards Marti El 28/09/2012 13:36, Lukas Jirkovsky escribió: > Hello, > did the behaviour of conversion from sRGB to Lab changed in the lcms 2.4? > > After update to 2.4 I get different results from what I used to get > with older lcms versions. The values used to be somewhere in range > [0,1], but now the values seems to be in range [0-100?]. > > For example, assume the conversion conversion from uint8 sRGB: > {63, 63, 63} > to Lab float. > > With older lcms versions I got: > {0.275746, 0.502007, 0.501945} > but now I get: > {27.5745792, 0.0116731515, -0.00389105058} > > Is this change intentional? > > The profiles are created using the cmsCreate_sRGBProfile() function > for RGB and cmsCreateLab4Profile(0) for Lab. > > Regards, > Lukas > > ------------------------------------------------------------------------------ > Got visibility? > Most devs has no idea what their production app looks like. > Find out how fast your code is with AppDynamics Lite. > http://ad.doubleclick.net/clk;262219671;13503038;y? > http://info.appdynamics.com/FreeJavaPerformanceDownload.html > _______________________________________________ > Lcms-user mailing list > Lcms-user@lists.sourceforge.net > https://lists.sourceforge.net/lists/listinfo/lcms-user > ------------------------------------------------------------------------------ Got visibility? Most devs has no idea what their production app looks like. Find out how fast your code is with AppDynamics Lite. http://ad.doubleclick.net/clk;262219671;13503038;y? http://info.appdynamics.com/FreeJavaPerformanceDownload.html _______________________________________________ Lcms-user mailing list Lcms-user@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/lcms-user