Quoting Dominik Kucma <dku...@gmail.com>:

> Now i need to extend it o read not only from CMYK profiles but also from
> other prtr profiles including 6CLR profiles. I'm able to list all named
> colors from profile, but I dont know how to get lab values for 6 element

Hi,

Named color profiles are a different beast. What you have is a normal  
6 channel output profile, and for those you need a buffer with 6  
channels. Format descriptor is TYPE_CMYK6_8 (and derivatives)

Regards
Marti


------------------------------------------------------------------------------