Thanks Eric and Octave. 

I was able to dump the config and import it. But I could not bind the domain.

sunlic1-ldom # ldm bind-domain nysunlic1
No matching volume vol1-nysunlic1 for vds server with name primary-vds0
Unable to bind client vdisk1
No matching volume vol2-nysunlic1 for vds server with name primary-vds0
Unable to bind client vdisk2
sunlic1-ldom # 
sunlic1-ldom # pwd  
/
sunlic1-ldom # cd /opt
sunlic1-ldom # more jayanthi.xml
<?xml version="1.0"?>
<LDM_interface version="1.0">
  <data version="2.0">
    <ldom>
      <ldom_info>
        <ldom_name>nysunlic1</ldom_name>
      </ldom_info>
      <cpu>
        <number>56</number>
      </cpu>
      <memory>
        <size>4108M</size>
      </memory>
      <network>
        <vnet_name>vnet0</vnet_name>
        <service_name>primary-vsw0</service_name>
      </network>
      <network>
        <vnet_name>vnet1</vnet_name>
        <service_name>primary-vsw1</service_name>
      </network>
      <disk>
        <vdisk_name>vdisk1</vdisk_name>
        <service_name>primary-vds0</service_name>
        <vol_name>vol1-nysunlic1</vol_name>
      </disk>
      <disk>
        <vdisk_name>vdisk2</vdisk_name>
        <service_name>primary-vds0</service_name>
        <vol_name>vol2-nysunlic1</vol_name>
      </disk>
      <var>
        <name>auto-boot?</name>
        <value>false</value>
      </var>
      <var>
        <name>boot-device</name>
        <value>pri_os sec_os</value>
      </var>
      <var>
        <name>keyboard-layout</name>
        <value>US-English</value>
      </var>
      <var>
        <name>local-mac-address?</name>
        <value>true</value>
      </var>
      <var>
        <name>nvramrc</name>
        <value>devalias pri_os /virtual-devices at 100/channel-devices at 
200/disk at 0:a
devalias sec_os /virtual-devices at 100/channel-devices at 200/disk at 1:a
devalias BLP1_200812112217_up27.3d /virtual-devices at 100/channel-devices at 
200/disk at 0
devalias BLP1_200901042258_up23.3d /virtual-devices at 100/channel-devices at 
200/disk at 0:a</va
lue>
      </var>
      <var>
        <name>use-nvramrc?</name>
        <value>true</value>
      </var>
    </ldom>
  </data>
</LDM_interface>
sunlic1-ldom # 
sunlic1-ldom # 
sunlic1-ldom # 
sunlic1-ldom # 
sunlic1-ldom # pwd
/opt
sunlic1-ldom # ldm list-bindings | more
NAME             STATE    FLAGS   CONS    VCPU  MEMORY   UTIL  UPTIME
primary          active   -n-cv   SP      8     1G       4.5%  11m

MAC
    00:21:28:05:3b:6c

VCPU
    VID    PID    UTIL STRAND
    0      0       14%   100%
    1      1      2.8%   100%
    2      2      1.9%   100%
    3      3      0.7%   100%
    4      4       11%   100%
    5      5      3.2%   100%
    6      6      1.4%   100%
    7      7      0.6%   100%

MAU
    CPUSET
    (0, 1, 2, 3, 4, 5, 6, 7)

MEMORY
    RA               PA               SIZE            
    0xe000000        0xe000000        1G

VARIABLES
    auto-boot?=false
    boot-device=/pci at 400/pci at 0/pci at 8/scsi at 0/disk at 0,0:a disk net
    keyboard-layout=US-English
    local-mac-address?=true
    nvramrc=devalias net /pci at 500/pci at 0/pci at 8/network at 0
." ChassisSerialNumber BEL083337V " cr
devalias BLP1_200901042222_up104.5d /pci at 400/pci at 0/pci at 8/scsi at 
0/disk at 0,0
    security-mode=none
    security-password=

IO
    DEVICE           PSEUDONYM        OPTIONS
    pci at 400          pci_0           
    pci at 500          pci_1           

VDS
    NAME             VOLUME         OPTIONS          DEVICE
    primary-vds0     vol1-sunlic1-new                  
/export1/sunlic1-bootdisk1
                     vol2-sunlic1-new                  
/export2/sunlic1-bootdisk2

VCC
    NAME             PORT-RANGE
    primary-vcc0     5000-5100

VSW
    NAME             MAC               NET-DEV   DEVICE     MODE
    primary-vsw0     00:14:4f:f8:ce:4b nxge4     switch at 0   prog,promisc
    primary-vsw1     00:14:4f:f9:dd:61 nxge5     switch at 1   prog,promisc
    primary-vsw2     00:14:4f:fb:d5:f0 nxge6     switch at 2   prog,promisc
    primary-vsw3     00:14:4f:f9:47:8c nxge7     switch at 3   prog,promisc

VCONS
    NAME             SERVICE                     PORT
    SP

------------------------------------------------------------------------------
NAME             STATE    FLAGS   CONS    VCPU  MEMORY   UTIL  UPTIME
nysunlic1        inactive -----           56    4108M          

VARIABLES
    auto-boot?=false
    boot-device=pri_os sec_os
    keyboard-layout=US-English
    local-mac-address?=true
    nvramrc=devalias pri_os /virtual-devices at 100/channel-devices at 200/disk 
at 0:a
devalias sec_os /virtual-devices at 100/channel-devices at 200/disk at 1:a
devalias BLP1_200812112217_up27.3d /virtual-devices at 100/channel-devices at 
200/disk at 0
devalias BLP1_200901042258_up23.3d /virtual-devices at 100/channel-devices at 
200/disk at 0:a
    use-nvramrc?=true

NETWORK
    NAME             SERVICE                     DEVICE     MAC
    vnet0            primary-vsw0                network at 0  00:14:4f:fa:0a:56
    NAME             SERVICE                     DEVICE     MAC
    vnet1            primary-vsw1                network at 1  00:14:4f:fb:53:31

DISK
    NAME             VOLUME                      TOUT DEVICE  SERVER          
    vdisk1           vol1-nysunlic1 at primary-vds0      disk at 0 
    vdisk2           vol2-nysunlic1 at primary-vds0      disk at 1 

VCONS
    NAME             SERVICE                     PORT
    nysunlic1        primary-vcc0                      

sunlic1-ldom # 
sunlic1-ldom # 

I can the see the  primary-vds0   with the old name. Could you please let me 
know how to change it? Can I remove the vds and re-create it? Could you please 
let me know.

Thanks Again!
Jayanthi
-- 
This message posted from opensolaris.org

Reply via email to