Update of /cvsroot/leaf/doc/guide/user-bering-uclibc In directory sc8-pr-cvs1.sourceforge.net:/tmp/cvs-serv8834
Modified Files: bucu-ppp.xml bucu-pppoa.xml bucu-pppoatm.xml bucu-pppoe.xml Log Message: additions for leaf.cfg package loading Index: bucu-pppoa.xml =================================================================== RCS file: /cvsroot/leaf/doc/guide/user-bering-uclibc/bucu-pppoa.xml,v retrieving revision 1.2 retrieving revision 1.3 diff -C2 -d -r1.2 -r1.3 *** bucu-pppoa.xml 6 Mar 2004 14:02:46 -0000 1.2 --- bucu-pppoa.xml 4 May 2004 20:03:18 -0000 1.3 *************** *** 26,29 **** --- 26,39 ---- <revhistory> <revision> + <revnumber>0.4</revnumber> + + <date>2004-05-04</date> + + <authorinitials>ES</authorinitials> + + <revremark>Update for leaf.cfg</revremark> + </revision> + + <revision> <revnumber>0.3</revnumber> *************** *** 79,82 **** --- 89,93 ---- <para>Boot a Bering floppy image. Once the LEAF menu appears get access to the linux shell by (q)uitting the menu. Edit the <filename>lrpkg.cfg</filename> + (pre Bering-uClibc-2.2.0) or <filename>leaf.cfg</filename> (Bering-uClibc-2.2.0 onwards) file and REPLACE the dhcpcd entry by ppp,pptp in the list of packages to be loaded at boot. Check the Bering <ulink *************** *** 84,99 **** to learn how to do that.</para> - <para>Your <filename>lrpkg.cfg</filename> file will then look like - (adjust to your tastes):</para> - - <screen> - root,etc,local,modules,iptables,ppp,pptp,keyboard,shorwall,ulogd,dnscache,weblet - </screen> - - <important> - <para>The line ("root ... dnscache,weblet") - must be typed as a single one in <filename>syslinux.cfg</filename></para> - </important> - <para>The ppp package is provided on the standard Bering-uClibc floppy. The pptp.lrp package is available <ulink --- 95,98 ---- Index: bucu-pppoatm.xml =================================================================== RCS file: /cvsroot/leaf/doc/guide/user-bering-uclibc/bucu-pppoatm.xml,v retrieving revision 1.3 retrieving revision 1.4 diff -C2 -d -r1.3 -r1.4 *** bucu-pppoatm.xml 11 Mar 2004 21:49:23 -0000 1.3 --- bucu-pppoatm.xml 4 May 2004 20:03:18 -0000 1.4 *************** *** 44,47 **** --- 44,58 ---- <revremark>Update for Bering-uClibc</revremark> </revision> + + <revision> + <revnumber>0.5</revnumber> + + <date>2004-05-04</date> + + <authorinitials>ES</authorinitials> + + <revremark>Update for leaf.cfg</revremark> + </revision> + </revhistory> </chapterinfo> *************** *** 75,94 **** <para>Boot your Bering-uClibc floppy image. Once the LEAF menu appears get access to the linux shell by (q)uitting the menu. Edit the <filename>lrpkg.cfg</filename> file and REPLACE the dhcpcd entry by pppoatm and libatm in the list of packages to be loaded at boot. Check the Bering-uClibc <ulink url="http://leaf.sourceforge.net/doc/guide/buci-install.html">installation guide</ulink> to learn how to do that.</para> - <para>Your <filename>lrpkg.cfg</filename> file will then look like - (adjust to your tastes):</para> - - <screen> - root,etc,local,modules,iptables,libatm,ppp,pppoatm,keyboard,shorwall,ulogd,dnscache,weblet - </screen> - - <important> - <para>The line ("root ... dnscache,weblet") - must be typed as a single one in <filename>lrpkg.cfg</filename></para> - </important> - <para>The pppoatm.lrp and libatm.lrp packages are available <ulink url="http://cvs.sourceforge.net/viewcvs.py/leaf/bin/packages/uclibc-0.9/20/">here</ulink>.</para> --- 86,94 ---- <para>Boot your Bering-uClibc floppy image. Once the LEAF menu appears get access to the linux shell by (q)uitting the menu. Edit the <filename>lrpkg.cfg</filename> + (pre Bering-uClibc-2.2.0) or <filename>leaf.cfg</filename> (Bering-uClibc-2.2.0 onwards) file and REPLACE the dhcpcd entry by pppoatm and libatm in the list of packages to be loaded at boot. Check the Bering-uClibc <ulink url="http://leaf.sourceforge.net/doc/guide/buci-install.html">installation guide</ulink> to learn how to do that.</para> <para>The pppoatm.lrp and libatm.lrp packages are available <ulink url="http://cvs.sourceforge.net/viewcvs.py/leaf/bin/packages/uclibc-0.9/20/">here</ulink>.</para> Index: bucu-ppp.xml =================================================================== RCS file: /cvsroot/leaf/doc/guide/user-bering-uclibc/bucu-ppp.xml,v retrieving revision 1.12 retrieving revision 1.13 diff -C2 -d -r1.12 -r1.13 *** bucu-ppp.xml 8 Mar 2004 21:49:41 -0000 1.12 --- bucu-ppp.xml 4 May 2004 20:03:17 -0000 1.13 *************** *** 25,28 **** --- 25,39 ---- <revhistory> + + <revision> + <revnumber>0.4</revnumber> + + <date>2004-05-04</date> + + <authorinitials>ES</authorinitials> + + <revremark>Update for leaf.cfg</revremark> + </revision> + <revision> <revnumber>0.3</revnumber> *************** *** 92,112 **** <para>Boot a Bering-uClibc floppy image. Once the LEAF menu appears get ! access to the linux shell by (q)uitting the menu. Edit the ! <filename>lrpkg.cfg</filename> file and replace the dhcpcd entry by ppp in ! the list of packages to be loaded at boot. Check the Bering <ulink ! url="http://leaf.sourceforge.net/doc/guide/buci-install.html">installation ! guide</ulink> to learn how to do that.</para> ! ! <para>Your <filename>lrpkg.cfg</filename> file could look like (adjust to ! your tastes):</para> ! ! <screen> ! root,etc,local,modules,iptables,ppp,keyboard,shorwall,ulogd,dnscache,weblet ! </screen> ! ! <important> ! <para>The line ("root ... dnscache,weblet") must be typed as a single ! one in <filename>lrpkg.cfg</filename></para> ! </important> </section> --- 103,111 ---- <para>Boot a Bering-uClibc floppy image. Once the LEAF menu appears get ! access to the linux shell by (q)uitting the menu. Edit the <filename>lrpkg.cfg</filename> ! (pre Bering-uClibc-2.2.0) or <filename>leaf.cfg</filename> (Bering-uClibc-2.2.0 onwards) ! file and replace the dhcpcd entry by ppp in the list of packages to be loaded at boot. ! Check the Bering <ulink url="http://leaf.sourceforge.net/doc/guide/buci-install.html">installation guide</ulink> ! to learn how to do that.</para> </section> Index: bucu-pppoe.xml =================================================================== RCS file: /cvsroot/leaf/doc/guide/user-bering-uclibc/bucu-pppoe.xml,v retrieving revision 1.5 retrieving revision 1.6 diff -C2 -d -r1.5 -r1.6 *** bucu-pppoe.xml 8 Mar 2004 19:54:07 -0000 1.5 --- bucu-pppoe.xml 4 May 2004 20:03:18 -0000 1.6 *************** *** 26,29 **** --- 26,39 ---- <revhistory> <revision> + <revnumber>0.4</revnumber> + + <date>2004-05-04</date> + + <authorinitials>ES</authorinitials> + + <revremark>Update for leaf.cfg</revremark> + </revision> + + <revision> <revnumber>0.3</revnumber> *************** *** 85,88 **** --- 95,99 ---- <para>Boot a Bering floppy image. Once the LEAF menu appears get access to the linux shell by (q)uitting the menu. Edit the <filename>lrpkg.cfg</filename> + (pre Bering-uClibc-2.2.0) or <filename>leaf.cfg</filename> (Bering-uClibc-2.2.0 onwards) file and REPLACE the dhcpcd entry by ppp,pppoe in the list of packages to be loaded at boot. Check the Bering-uClibc <ulink *************** *** 90,106 **** guide</ulink> to learn how to do that.</para> - <para>Your <filename>lrpkg.cfg</filename> file will then look like (adjust - to your tastes):</para> - - <screen> - root,etc,local,modules,iptables,ppp,pppoe,keyboard,shorwall,ulogd,dnscache,weblet - </screen> - - <important> - <para>The line ("root ... dnscache,weblet") must be typed as a - single one in <filename>lrpkg.cfg</filename></para> - </important> - </section> - <section> <title>Step 2: declare the ppp and pppoe modules</title> --- 101,104 ---- ------------------------------------------------------- This SF.Net email is sponsored by: Oracle 10g Get certified on the hottest thing ever to hit the market... Oracle 10g. Take an Oracle 10g class now, and we'll give you the exam FREE. http://ads.osdn.com/?ad_id=3149&alloc_id=8166&op=click _______________________________________________ Leaf-cvs-commits mailing list [EMAIL PROTECTED] https://lists.sourceforge.net/lists/listinfo/leaf-cvs-commits