On Tue, 11 Feb 2003, Lynn Avants wrote: > On Tuesday 11 February 2003 09:28 pm, David Pitts wrote: > > That was the odd thing. No error messages that I could see, it just > > didn't work on boot, although it was fine from the command line. > > OK, come to think about it there is another possible init problem that > I haven't considered. If two or more init scripts share the same > rc# only one of the scripts (or none) are run. If there is a conflict > with another script on the system, the udhcpd script may not be > run at all on boot.
My understanding it is that the RCDLINKS data are converted to symbolic links in the various runlevel directories, and then the scripts are executed in alphabetical order. Thus, where the rc#'s are the same, the scripts are run in alphabetical order as a fallback... which may or may not meet your sequencing requirements, but should never result in a script not being run. > I ran into this when I packaged lcd.lrp, so I'll do > some checking and see if I can resolve the issue. Thanks for your > patience. --------------------------------------------------------------------------- Jeff Newmiller The ..... ..... Go Live... DCN:<[EMAIL PROTECTED]> Basics: ##.#. ##.#. Live Go... Live: OO#.. Dead: OO#.. Playing Research Engineer (Solar/Batteries O.O#. #.O#. with /Software/Embedded Controllers) .OO#. .OO#. rocks...2k --------------------------------------------------------------------------- ------------------------------------------------------- This SF.NET email is sponsored by: SourceForge Enterprise Edition + IBM + LinuxWorld = Something 2 See! http://www.vasoftware.com ------------------------------------------------------------------------ leaf-user mailing list: [EMAIL PROTECTED] https://lists.sourceforge.net/lists/listinfo/leaf-user SR FAQ: http://leaf-project.org/pub/doc/docmanager/docid_1891.html