Am 08.08.2016 um 11:34 schrieb Matthias Schiffer:
On 08/07/2016 10:24 PM, Mathias Kresin wrote:
Due to the missing carrier status set, the interface wasn't usable on a
BTHOMEHUB2B after ip link down and up as it is done in preinit.
Signed-off-by: Mathias Kresin <d...@kresin.me>
---
target/linux/generic/files/drivers/net/phy/adm6996.c | 11 +++++++++++
1 file changed, 11 insertions(+)
diff --git a/target/linux/generic/files/drivers/net/phy/adm6996.c
b/target/linux/generic/files/drivers/net/phy/adm6996.c
index a2ff2b0..7823b8b 100644
--- a/target/linux/generic/files/drivers/net/phy/adm6996.c
+++ b/target/linux/generic/files/drivers/net/phy/adm6996.c
@@ -1052,6 +1052,17 @@ static int adm6996_read_status(struct phy_device *phydev)
phydev->speed = SPEED_100;
phydev->duplex = DUPLEX_FULL;
phydev->link = 1;
+
+ if (phydev->link) {
This doesn't look right. You test phydev->link right after it is set to 1,
so the else branch doesn't do anything.
Well spotted! Stupid copy and paste leftover. Will send an updated
version in a few minutes.
Mathias
_______________________________________________
Lede-dev mailing list
Lede-dev@lists.infradead.org
http://lists.infradead.org/mailman/listinfo/lede-dev