Hi Will,

Yes you're right. Must have missed this when reading the sheet.
Thank you for your time!

Regards
Mikael

Will Zhang skrev 2010-10-13 12:26:
Hi Mikael,

I found the following text in the FT2232H data sheet:

3.4.2 FT2232H pins used in an FT245 Style Synchronous FIFO Interface

"In this mode the 'B' channel is not available as all resources have been switched onto channel A."

Regards

Will


On Wed, Oct 13, 2010 at 9:17 PM, Mikael Krus <m...@omnisys.se <mailto:m...@omnisys.se>> wrote:

    Hi Will,

    If I read the datasheet correct, single channel means that the
    synchronous FIFO mode is only available in interface A and not in B.
    So you mean if I choose this mode in interface A, interface B must
    be unconfigured?

    Regards
    Mikael

    Will Zhang skrev 2010-10-13 11:06:
    Hi Mikael,

    To my knowledge, FT2232H supports SINGLE CHANNEL synchronous FIFO
    mode. I suggest double check the data sheet to make sure your
    desired configuration is possible in hardware.

    Will

    On Wed, Oct 13, 2010 at 7:13 PM, Mikael Krus <m...@omnisys.se
    <mailto:m...@omnisys.se>> wrote:

         Hi,

        I am trying to configure both interfaces in FT2232H, and use
        them and at the same time. This isn't working as expected though.

        This is how I like it:
        Interface A should be in synchrounous FIFO mode continously
        reading the buffer waiting for data.
        Interface B should be in MPSSE mode (simple general purpose
        IO). Toggling a pin writes data to the FIFO (for interface A
        to read).

        This is a snippet from my code when sertting up the
        interfaces (I can attach my full code if someone like to see it):

           // Select and open interface A, reset and purge, enable
        syncFIFO
           ret = ftdi_set_interface(&ftdicA, INTERFACE_A);
           ret |= ftdi_usb_open_dev(&ftdicA, devlist->dev);
           ret |= ftdi_usb_reset(&ftdicA);
           ret |= ftdi_usb_purge_buffers(&ftdicA);
           ret |= ftdi_set_bitmode(&ftdicA, 0, BITMODE_RESET);
           ret |= ftdi_set_bitmode(&ftdicA, 0, BITMODE_SYNCFF);

           ret = ftdi_set_interface(&ftdicB, INTERFACE_B);
           ret |= ftdi_usb_open_dev(&ftdicB, devlist->dev);
           ret |= ftdi_usb_reset(&ftdicB);
           ret |= ftdi_usb_purge_buffers(&ftdicB);
           ret |= ftdi_set_bitmode(&ftdicB, 0, BITMODE_RESET);
           ret |= ftdi_set_bitmode(&ftdicB, 0, BITMODE_MPSSE);

        After this I try to send a "bogus" command to the MPSSE
        expecting it to send back a two byte "error code" message,
        but this never happens.

        If I comment out the setup of interface A, however it works
        as expected (regarding the "error message" sent back).
        What did I do wrong??

        Besides this, what effect will my ftdi_usb_reset() call have
        on interface A when calling it for interface B? Does it also
        get reset?

        Best regards
        Mikael

        --
        libftdi - see http://www.intra2net.com/en/developer/libftdi
        for details.
        To unsubscribe send a mail to
        libftdi+unsubscr...@developer.intra2net.com
        <mailto:libftdi%2bunsubscr...@developer.intra2net.com>



    ------------------------------------------------------------------------

    *libftdi* - see http://www.intra2net.com/en/developer/libftdi for
    details.
    To unsubscribe send a mail to
    libftdi+unsubscr...@developer.intra2net.com
    <mailto:libftdi+unsubscr...@developer.intra2net.com>



-- Mikael Krus,M.Sc.EE <http://M.Sc.EE>
    Omnisys Instruments AB
    August Barks Gata 6B
    SE-421 32 Västra Frölunda
    Sweden

    Phone:  +46 31 734 34 10
    http://www.omnisys.se


    ------------------------------------------------------------------------

    *libftdi* - see http://www.intra2net.com/en/developer/libftdi for
    details.
    To unsubscribe send a mail to
    libftdi+unsubscr...@developer.intra2net.com
    <mailto:libftdi+unsubscr...@developer.intra2net.com>




------------------------------------------------------------------------

*libftdi* - see http://www.intra2net.com/en/developer/libftdi for details.
To unsubscribe send a mail to libftdi+unsubscr...@developer.intra2net.com <mailto:libftdi+unsubscr...@developer.intra2net.com>



--
Mikael Krus, M.Sc.EE
Omnisys Instruments AB
August Barks Gata 6B
SE-421 32 Västra Frölunda
Sweden

Phone:  +46 31 734 34 10
http://www.omnisys.se



--
libftdi - see http://www.intra2net.com/en/developer/libftdi for details.
To unsubscribe send a mail to libftdi+unsubscr...@developer.intra2net.com   

Reply via email to