https://bugs.documentfoundation.org/show_bug.cgi?id=162064

--- Comment #6 from Bartosz <[email protected]> ---
Every page scale has it's own unit (like milimeters:

            <Cell N='PageScale' V='0.03937007874015748' U='MM'/>
            <Cell N='DrawingScale' V='0.03937007874015748' U='MM'/>

With current implementation of libvisio, unit is not taking into account.

For example scale could be in inches:

            <Cell N='PageScale' V='1' U='IN'/>
            <Cell N='DrawingScale' V='1' U='IN_F'/>

The default value of the structure is one inch.

-- 
You are receiving this mail because:
You are the assignee for the bug.