https://bugs.documentfoundation.org/show_bug.cgi?id=92693

            Bug ID: 92693
           Summary: EDITING: Function MINUTE() always 1 minute greater
                    than minute in timefield/timestampfield in
                    ReportDesigner
           Product: LibreOffice
           Version: unspecified
          Hardware: Other
                OS: Linux (All)
            Status: UNCONFIRMED
          Severity: normal
          Priority: medium
         Component: Base
          Assignee: [email protected]
          Reporter: [email protected]

Created attachment 117191
  --> https://bugs.documentfoundation.org/attachment.cgi?id=117191&action=edit
Open the report report_hour_minute_second. MINUTE gives wrong value.

Open the attached database.
Open the report report_hour_minute_second.
You could see the timestampfields and timefields. There is extracted also the
value for HOUR, MINUTE and SECOND. All extracted values for MINUTE are 1 minute
greater than the right value of the timestampfields or timefields.

Tried to get the TIMEVALUE this way because of bug92654, but got another bug.

-- 
You are receiving this mail because:
You are the assignee for the bug.
_______________________________________________
Libreoffice-bugs mailing list
[email protected]
http://lists.freedesktop.org/mailman/listinfo/libreoffice-bugs

Reply via email to