On 28 Jun 2012 Pete Batard Wrote:
 > To eliminate the compiler, can you please download the
 > libusbx-1.0.12-win.7z from
 > http://sourceforge.net/projects/libusbx/files/releases/1.0.12/Windows/
 > and run the xusb.exe you find there in examples/bin32, prerablly with
 > LIBUSB_DEBUG=4. If you get the same error, then we can eliminate BC++ 
 > as the possible cause.

 > Also the information I get for VID_10C4&PID_0001 according to [1]), is
 > that it's an HID touch screen kit. Is that correct?

The xusb.exe in released 1.0.12 also have the same result.

I think the problem mostly was caused by my device. It is a device
I had built years ago using Silabs' F8051F320 and their Development tool
Version 2.2 with included HID example source.

Today I use three utilities(HIDTest.exe, SimpleHIWrite.exe and
USBDeview.exe) to check my device. The first two were hung when their
"Device Info" or "Info" button was pressed, and has to force to close.
The third one works normally but I think it is because it didn't touch
the configuration descriptor.

Also use the "Advanced USB port monitor" to check. The device was
listed as "disconnected"? By double clicks it, a info window pop out
shows the Device descriptor and Endpoint descriptor, but no
Configuration and Interface descriptors in it.

It's my device's problem, have to figure it out. But some hints from you
experts should be helpful:-)

Best Regards,
Jach





------------------------------------------------------------------------------
Live Security Virtual Conference
Exclusive live event will cover all the ways today's security and 
threat landscape has changed and how IT managers can respond. Discussions 
will include endpoint security, mobile security and the latest in malware 
threats. http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/
_______________________________________________
libusbx-devel mailing list
libusbx-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/libusbx-devel

Reply via email to