On 21 March 2012 07:46, Turquette, Mike <mturque...@ti.com> wrote: ... > As mentioned above, you'll still need to check for CLK_SET_RATE_PARENT > in your .round_rate implementation with __clk_get_flags(hw->clk). > For my particular case, the clk is PLL with fixed rate clk (oscillator) as parent. It's known that flag CLK_SET_RATE_PARENT will never be set for this type of clks.
> Did you want to send a formal patch or just have me absorb this into > the fixes I'm brewing already? I've already fixed the potential null > ptr dereferences in clk_calc_new_rates, but that's no big deal. > The code was attached for better discussion, and I would leave the formal patch to you. Regards, Shawn _______________________________________________ linaro-dev mailing list linaro-dev@lists.linaro.org http://lists.linaro.org/mailman/listinfo/linaro-dev