Hello Zaba, > wlr-2.25 runs fine; however I see a "1.#J" display in the Floor level after > pressing the Amplitude Margins (A) button while wlr is up and running.
Ooooh!! This turns out to be an error I just introduced. If you run the seconf fft on an uncalibrated system the variables fft1_first_inband and fft1_last_inband become un-initialized. Sorry. Set them like this: fft1_first_inband=0; fft1_last_inband=fft1_size-1; first thing in void set_fft1_endpoints(void), row 783 in fft1.c Both become zero automatically when not initiated at all. As a result the noise blanker might not work properly if there is a strong signal close to the selected frequency. This error was not present in previous versions. Thanks for the bug report, Zaba. I will wait for about a week for more bug reports before I upload the corrected version. 73 Leif / SM5BSZ ############################################################# This message is sent to you because you are subscribed to the mailing list <linrad@antennspecialisten.se>. To unsubscribe, E-mail to: <[EMAIL PROTECTED]> To switch to the DIGEST mode, E-mail to <[EMAIL PROTECTED]> To switch to the INDEX mode, E-mail to <[EMAIL PROTECTED]> Send administrative queries to <[EMAIL PROTECTED]>