Hello!

I succeed in couple CTC pairs in zVM, but in the booted Linux I get "Error
during RX init handshake"

Where I am wrong? Whats with that handshake error?


I did it like that (configs/profiles at bottom of mail)...

login with li1000:

LOGON LI1000
02: z/VM Version 4 Release 2.0, Service Level 0101 (64-bit),
02: built on IBM Virtualization Technology
02: There is no logmsg data
02: FILES:   NO RDR,   NO PRT,   NO PUN
02: RECONNECTED AT 12:31:12 EST TUESDAY 04/02/02
> i cms
z/VM V4.2.0    2002-01-29 09:09
DMSVML2060I TCPMAINT 592 linked as 0120 file mode Z
02: CTCA 1000 COUPLED TO VMIP 1001
02: CTCA 1001 COUPLED TO VMIP 1000
Ready; T=0.01/0.01 12:31:33


then "IPL 946C"
after IPL and logon to Linux and:

[root@linuxgigaxa root]# insmod ctc
insmod ctc
Using /lib/modules/2.4.7-0.24.23tape/kernel/drivers/s390/net/ctc.o
[root@linuxgigaxa root]#
[root@linuxgigaxa root]# ifconfig ctc0 57.20.91.169
ifconfig ctc0 57.20.91.169
ctc0: Error during TX init handshake
ctc0: Error during RX init handshake
[root@linuxgigaxa root]#

after a while (2 min?):
[root@linuxgigaxa root]# CTCA 1001 DROPPED BY VMIP 1000
CTCA 1000 DROPPED BY VMIP 1001

...and the VMIP guest is dropped from zVM.

I have to "halt" linux li1000, "disc" li1000 , login with AUTOLOG1 to get
VMIP up again, and login with li1000 again to get the CTC coupled again...






Configurations...


**TCPMAINT:Profile.tcpip**
DEVICE LI1000  CTC 1000
LINK   ZVMVC1000  CTC 0     LI1000

HOME
  57.20.91.170 ZVMVC1000

GATEWAY
  57.20.91.169  =            ZVMVC1000 1492         HOST


**MAINT:User.direct:**
USER VMIP VMIP 32M 128M ABG
  INCLUDE TCPCMSU
  OPTION QUICKDSP SVMSTAT MAXCONN 1024 DIAG98 APPLMON
  SHARE RELATIVE 3000
  IUCV ALLOW
  IUCV ANY PRIORITY
  IUCV *CCS PRIORITY MSGLIMIT 255
  SPECIAL 1000 CTCA LI1000
  SPECIAL 1001 CTCA LI1000
  LINK TCPMAINT 592 592 RR * TCPIP tools disk
  MDISK 191 3390 0096 001 420W02  MR READ     WRITE    MULTIPLE

USER Li1000 Li1000 256M 512M G
 MACHINE esa
 ACCOUNT 1234
 CPU 00 VECTOR
 CPU 02 NOVECTOR BASE
 IPL CMS PARM AUTOCR
 IUCV ANY
 IUCV ALLOW
 CONSOLE 009 3215
 SPOOL 00C 2540 READER *
 SPOOL 00D 2540 PUNCH A
 SPOOL 00E 1403 A
 LINK MAINT 0190 0190 RR * CMS system disk
 LINK MAINT 019D 019D RR * help disk
 LINK MAINT 019E 019E RR * Product code disk
 SPECIAL 1000 CTCA VMIP
 SPECIAL 1001 CTCA VMIP
 DEDICATE 92EB 92EB
 DEDICATE 946C 946C
 MDISK 191 3390 3336 001 420W01  MR READ     WRITE    MULTIPLE



/*PROFILE Li1000*/
'SET PF12 RETR'
/*'IPL 946B'*/
'VMFCLEAR'
'CP SET MSG ON'
'CP SET EMSG ON'
'SET IMPCP ON'
'SET RUN ON'
'CP TERM CHARDEL OFF'
'VMLINK TCPMAINT 592 ( NONAMES'
'CP SET PF10 RETR'
'CP SET RETR MAX'
'CP TERM HOLD OFF'
'CP COUPLE 1000 VMIP 1001'
'CP COUPLE 1001 VMIP 1000'






> Frank Schwede
> Product Manager IBM High-End System Software
>
> Lufthansa Systems Infratec GmbH
> FRA AR / ISS (IBM System Services)
> Am Weiher 24, Geb. B, Raum 7.1.18
> D 65451 Kelsterbach
>
> Tel   +49 69 696 94878
> Fax  +49 69 696 93488
> mailto:[EMAIL PROTECTED]
> http://www.LHsystems.com
>
>

Reply via email to