Hello! I succeed in couple CTC pairs in zVM, but in the booted Linux I get "Error during RX init handshake"
Where I am wrong? Whats with that handshake error? I did it like that (configs/profiles at bottom of mail)... login with li1000: LOGON LI1000 02: z/VM Version 4 Release 2.0, Service Level 0101 (64-bit), 02: built on IBM Virtualization Technology 02: There is no logmsg data 02: FILES: NO RDR, NO PRT, NO PUN 02: RECONNECTED AT 12:31:12 EST TUESDAY 04/02/02 > i cms z/VM V4.2.0 2002-01-29 09:09 DMSVML2060I TCPMAINT 592 linked as 0120 file mode Z 02: CTCA 1000 COUPLED TO VMIP 1001 02: CTCA 1001 COUPLED TO VMIP 1000 Ready; T=0.01/0.01 12:31:33 then "IPL 946C" after IPL and logon to Linux and: [root@linuxgigaxa root]# insmod ctc insmod ctc Using /lib/modules/2.4.7-0.24.23tape/kernel/drivers/s390/net/ctc.o [root@linuxgigaxa root]# [root@linuxgigaxa root]# ifconfig ctc0 57.20.91.169 ifconfig ctc0 57.20.91.169 ctc0: Error during TX init handshake ctc0: Error during RX init handshake [root@linuxgigaxa root]# after a while (2 min?): [root@linuxgigaxa root]# CTCA 1001 DROPPED BY VMIP 1000 CTCA 1000 DROPPED BY VMIP 1001 ...and the VMIP guest is dropped from zVM. I have to "halt" linux li1000, "disc" li1000 , login with AUTOLOG1 to get VMIP up again, and login with li1000 again to get the CTC coupled again... Configurations... **TCPMAINT:Profile.tcpip** DEVICE LI1000 CTC 1000 LINK ZVMVC1000 CTC 0 LI1000 HOME 57.20.91.170 ZVMVC1000 GATEWAY 57.20.91.169 = ZVMVC1000 1492 HOST **MAINT:User.direct:** USER VMIP VMIP 32M 128M ABG INCLUDE TCPCMSU OPTION QUICKDSP SVMSTAT MAXCONN 1024 DIAG98 APPLMON SHARE RELATIVE 3000 IUCV ALLOW IUCV ANY PRIORITY IUCV *CCS PRIORITY MSGLIMIT 255 SPECIAL 1000 CTCA LI1000 SPECIAL 1001 CTCA LI1000 LINK TCPMAINT 592 592 RR * TCPIP tools disk MDISK 191 3390 0096 001 420W02 MR READ WRITE MULTIPLE USER Li1000 Li1000 256M 512M G MACHINE esa ACCOUNT 1234 CPU 00 VECTOR CPU 02 NOVECTOR BASE IPL CMS PARM AUTOCR IUCV ANY IUCV ALLOW CONSOLE 009 3215 SPOOL 00C 2540 READER * SPOOL 00D 2540 PUNCH A SPOOL 00E 1403 A LINK MAINT 0190 0190 RR * CMS system disk LINK MAINT 019D 019D RR * help disk LINK MAINT 019E 019E RR * Product code disk SPECIAL 1000 CTCA VMIP SPECIAL 1001 CTCA VMIP DEDICATE 92EB 92EB DEDICATE 946C 946C MDISK 191 3390 3336 001 420W01 MR READ WRITE MULTIPLE /*PROFILE Li1000*/ 'SET PF12 RETR' /*'IPL 946B'*/ 'VMFCLEAR' 'CP SET MSG ON' 'CP SET EMSG ON' 'SET IMPCP ON' 'SET RUN ON' 'CP TERM CHARDEL OFF' 'VMLINK TCPMAINT 592 ( NONAMES' 'CP SET PF10 RETR' 'CP SET RETR MAX' 'CP TERM HOLD OFF' 'CP COUPLE 1000 VMIP 1001' 'CP COUPLE 1001 VMIP 1000' > Frank Schwede > Product Manager IBM High-End System Software > > Lufthansa Systems Infratec GmbH > FRA AR / ISS (IBM System Services) > Am Weiher 24, Geb. B, Raum 7.1.18 > D 65451 Kelsterbach > > Tel +49 69 696 94878 > Fax +49 69 696 93488 > mailto:[EMAIL PROTECTED] > http://www.LHsystems.com > >
