John,

Thanks for the info.  I will try this.  I'll have to read up on the CUADDR parameter, 
as I'm not really sure exactly what it does.  I will install this change dynamically.

I'll have to study this some more tomorrow.  Time to go home now.

Eric Bielefeld
Sr. MVS Systems Programmer
P&H Mining Equipment
Milwaukee, WI
414-671-7849
[EMAIL PROTECTED]

>>> [EMAIL PROTECTED] 03/17/03 03:31PM >>>
One thing that I noticed immediately is that your CNTLUNIT macro had
CUADDR=0 on both of them. This is wrong. Here is our defination:

         CHPID PATH=(32),SHARED,                                       *
               PARTITION=((LP1,MAIN,RDC1,SMC1,TECH,ZVM),(LP1,MAIN,RDC1,*
               SMC1,TECH,ZVM)),TYPE=CTC
         CHPID PATH=(3F),SHARED,                                       *
               PARTITION=((LP1,MAIN,RDC1,SMC1,TECH,ZVM),(LP1,MAIN,RDC1,*
               SMC1,TECH,ZVM)),TYPE=CNC
*
* IN THE FOLLOWING CNTLUNIT MACROS, THE CUADDR=N IS THE LPAR NUMBER
* 1 = MAIN
* 2 = LP1
* 3 = SMC1
* 4 = RDC1
* 5 = TECH
         CNTLUNIT CUNUMBR=3201,PATH=(32),UNITADD=((40,064)),CUADD=1,   *
               UNIT=SCTC
         CNTLUNIT CUNUMBR=3202,PATH=(32),UNITADD=((40,064)),CUADD=2,   *
               UNIT=SCTC
         CNTLUNIT CUNUMBR=3203,PATH=(32),UNITADD=((40,064)),CUADD=3,   *
               UNIT=SCTC
         CNTLUNIT CUNUMBR=3204,PATH=(32),UNITADD=((40,064)),CUADD=4,   *
               UNIT=SCTC
         CNTLUNIT CUNUMBR=3205,PATH=(32),UNITADD=((40,064)),CUADD=5,   *
               UNIT=SCTC
         CNTLUNIT CUNUMBR=3F01,PATH=(3F),UNITADD=((40,064)),CUADD=1,   *
               UNIT=SCTC
         CNTLUNIT CUNUMBR=3F02,PATH=(3F),UNITADD=((40,064)),CUADD=2,   *
               UNIT=SCTC
         CNTLUNIT CUNUMBR=3F03,PATH=(3F),UNITADD=((40,064)),CUADD=3,   *
               UNIT=SCTC
         CNTLUNIT CUNUMBR=3F04,PATH=(3F),UNITADD=((40,064)),CUADD=4,   *
               UNIT=SCTC
         CNTLUNIT CUNUMBR=3F05,PATH=(3F),UNITADD=((40,064)),CUADD=5,   *
               UNIT=SCTC
*
* NOTE THAT THERE ARE TWO IODEVICE MACROS FOR EVERY ADDRESS. ONE IS
* FOR ONE SIDE, THE OTHER IS FOR THE OTHER SIDE. PLEASE NOTE THAT
* THE PARTITION= ASSIGNED TO THE IODEVICE MUST BE THE OPPOSITE SIDE
* FROM THE PARTITION ASSIGNED VIA THE CUADDR= ON THE CNTLUNIT
* MACRO.
         IODEVICE ADDRESS=(F40,008),CUNUMBR=(3202),STADET=Y,           *
               PARTITION=(MAIN),UNIT=BCTC
         IODEVICE ADDRESS=(F40,008),CUNUMBR=(3F01),STADET=Y,           *
               PARTITION=(LP1),UNIT=BCTC
         IODEVICE ADDRESS=(F48,008),CUNUMBR=(3205),STADET=Y,           *
               PARTITION=(MAIN),UNIT=BCTC
         IODEVICE ADDRESS=(F48,008),CUNUMBR=(3F01),STADET=Y,           *
               PARTITION=(TECH),UNIT=BCTC
         IODEVICE ADDRESS=(F50,008),CUNUMBR=(3203),STADET=Y,           *
               PARTITION=(MAIN),UNIT=BCTC
         IODEVICE ADDRESS=(F50,008),CUNUMBR=(3F01),STADET=Y,           *
               PARTITION=(SMC1),UNIT=BCTC
         IODEVICE ADDRESS=(F60,008),CUNUMBR=(3204),STADET=Y,           *
               PARTITION=(MAIN),UNIT=BCTC
         IODEVICE ADDRESS=(F60,008),CUNUMBR=(3F01),STADET=Y,           *
               PARTITION=(RDC1),UNIT=BCTC
         IODEVICE ADDRESS=(F68,008),CUNUMBR=(3202),STADET=Y,           *
               PARTITION=(SMC1),UNIT=BCTC
         IODEVICE ADDRESS=(F68,008),CUNUMBR=(3F03),STADET=Y,           *
               PARTITION=(LP1),UNIT=BCTC
         IODEVICE ADDRESS=(F70,008),CUNUMBR=(3203),STADET=Y,           *
               PARTITION=(RDC1),UNIT=BCTC
         IODEVICE ADDRESS=(F70,008),CUNUMBR=(3F04),STADET=Y,           *
               PARTITION=(SMC1),UNIT=BCTC

--
John McKown
Senior Technical Specialist
UICI Insurance Center
Applications & Solutions Team
+1.817.255.3225


> -----Original Message-----
> From: Eric Bielefeld [mailto:[EMAIL PROTECTED] 
> Sent: Monday, March 17, 2003 2:54 PM
> To: [EMAIL PROTECTED] 
> Subject: IOCDS For an Escon CTC Connection
>
>
> Saturday, I was in to install my new IOCDS for Linux with a
> CTC definition so I can communicate with my Linux Lpar from
> my production TCPIP.  The devices on one side of the
> connection, the one defined as a CNC Chpid, do not come up
> online.  Here are my IOCDS definitions:
>
> CHPID PATH=(04),SHARED,
>       PARTITION=((LINUX1,PROD,TEST),(LINUX1,PROD,TEST)),
>       TYPE=CNC
> CHPID PATH=(05),SHARED,
>       PARTITION=((LINUX1,PROD,TEST),(LINUX1,PROD,TEST)),
>       TYPE=CTC
> CHPID PATH=(06),SHARED,PARTITION=((PROD,TEST),(PROD,TEST)),
>       TYPE=CNC
> CNTLUNIT CUNUMBR=0D00,PATH=(04),UNITADD=((00,008)),CUADD=0,
>       UNIT=SCTC
> CNTLUNIT CUNUMBR=0E00,PATH=(05),UNITADD=((00,008)),CUADD=0,
>       UNIT=SCTC
> IODEVICE ADDRESS=(D00,008),CUNUMBR=(0D00),STADET=Y,UNIT=SCTC
> IODEVICE ADDRESS=(E00,008),CUNUMBR=(0E00),STADET=Y,
>       PARTITION=(LINUX1,PROD,TEST),UNIT=SCTC
>
> The 8 IODEVICEs starting at E00 come up online, or I should
> say can be varied online.  The devices at D00 will not come
> up online.  If I issue  V E00,ONLINE   I get the following:
>
> RESPONSE=PROD
>  IEE103I UNIT 0D00     NOT BROUGHT ONLINE
>  IEE763I NAME= IECVIOPM CODE= 0000000400000000
>  IOS551I NO PATHS PHYSICALLY AVAILABLE
>  IEE764I END OF IEE103I    RELATED MESSAGES
>
> Why won't the E00 devices come up online.  Before I installed
> the new IOCDS, I went into the back of our MP3000-H50 and
> plugged an Escon cable between Chpids  04 and 05.  Hopefully
> someone knows if my coding is correct, or why the devices
> defined don't come up online.  Maybe this is normal.  I don't
> have my Linux1 Lpar running.  We don't have VM.
>
> I did notice that the E00 devices have the PARTITION keyword,
> and the D00 devices don't.  I didn't notice that before today
> when I looked at the IOCP deck I generated on Friday.  I
> don't think that should have anything to do with it, because
> both Chpid 04 and 05 have the PARTITION keyword for all Lpars.

+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
This electronic mail transmission contains information from P & H Mining Equipment
which is confidential, and is intended only for the use of the proper addressee.
If you are not the intended recipient, please notify us immediately at the return
address on this transmission, or by telephone at (414) 671-4400, and delete this
message and any attachments from your system.  Unauthorized use, copying,
disclosing, distributing, or taking any action in reliance on the contents of this
transmission is strictly prohibited and may be unlawful.
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++

Reply via email to