Mark;

This is the method the VMer's have used on all previous Linux instances, and it
has worked.  I'll ask them to comment and explain.  They are pretty good, so
I've just always accepted there methods.

Can you tell me what the prescribed method / process should be?  

Cheers;

E!

-----------------
Eric Wilson
IBM Certified Advanced Technical Expert 
RedHat Certified Engineer


-----Original Message-----
From: Mark Post [mailto:[EMAIL PROTECTED] 
Sent: Tuesday, 09 December, 2003 21:09
To: [EMAIL PROTECTED]
Subject: Re: VM DASD oddness

Eric,

Why are you running cpfmtxa on a minidisk?  That is normally only used for
_complete_ DASD volumes by the z/VM system programmer before carving it up
into minidisks.


Mark Post

-----Original Message-----
From: Linux on 390 Port [mailto:[EMAIL PROTECTED] Behalf Of
Wilson, Eric
Sent: Tuesday, December 09, 2003 4:17 PM
To: [EMAIL PROTECTED]
Subject: VM DASD oddness


Hey All;

I'm not a VM'er so please be gentle...

What does "Volume has an incompatable disk layout" mean?

We are trying to install RHEL v 3.0 on a particular VMGuest.  We have used
this
same code many times previous.  We are now not seeing any dasd devices in
anaconda, and we see the following on the console:

dasd(eckd): ECKD discipline initializing
dasd(eckd): /dev/dasda  ( 94:  0),[EMAIL PROTECTED]: 3390/0C(CU:3990/04) Cyl:188
Head:15 S
ec:224
dasd(eckd): /dev/dasda  ( 94:  0),[EMAIL PROTECTED]: 3390/0C(CU:3990/04):
Configuration da
ta read
dasd: No request IRQ
dasd(eckd): /dev/dasdb  ( 94:  4),[EMAIL PROTECTED]: 3390/0C(CU:3990/04) Cyl:740
Head:15 S
ec:224
dasd(eckd): /dev/dasdb  ( 94:  4),[EMAIL PROTECTED]: 3390/0C(CU:3990/04):
Configuration da
ta read
dasd(eckd): /dev/dasda  ( 94:  0),[EMAIL PROTECTED]: Volume has incompatible disk
layout
dasd: No request IRQ
dasd(eckd): /dev/dasdc  ( 94:  8),[EMAIL PROTECTED]: 3390/0A(CU:3990/04) Cyl:2928
Head:15
Sec:224
dasd(eckd): /dev/dasdb  ( 94:  4),[EMAIL PROTECTED]: Volume has incompatible disk
layout
dasd(eckd): /dev/dasdc  ( 94:  8),[EMAIL PROTECTED]: 3390/0A(CU:3990/04):
Configuration da
ta read
dasd: No request IRQ
dasd(eckd): /dev/dasdd  ( 94: 12),[EMAIL PROTECTED]: 3390/0C(CU:3990/04) Cyl:740
Head:15 S
ec:224


All the DASD was formated this way:

cpfmtxa
ENTER FORMAT, ALLOCATE, LABEL, OR QUIT:
format
ENTER THE VDEV TO BE PROCESSED OR QUIT:
200
ENTER THE CYLINDER RANGE TO BE FORMATTED ON DISK 0200 OR QUIT:
0-end
ENTER THE VOLUME LABEL FOR DISK 0200:
lnx200
CPFMTXA:
FORMAT WILL ERASE CYLINDERS 00000-00187 ON DISK 0200
DO YOU WANT TO CONTINUE? (YES | NO)
yes
HCPCCF6209I INVOKING ICKDSF.
ICK030E DEFINE INPUT  DEVICE: FN FT FM, "CONSOLE", OR "READER"
CONSOLE
ICK031E DEFINE OUTPUT DEVICE: FN FT FM, "CONSOLE", OR "PRINTER"
CONSOLE
ICKDSF - CMS/XA/ESA DEVICE SUPPORT FACILITIES 16.0                TIME:
11:33:04
        12/09/03     PAGE   1

ENTER INPUT COMMAND:
  CPVOL FMT MODE(ESA) UNIT(0200) VOLID(LNX200) NOVFY -
ENTER INPUT COMMAND:
 RANGE(0,187)
ICK00700I DEVICE INFORMATION FOR 0200 IS CURRENTLY AS FOLLOWS:
          PHYSICAL DEVICE = 3390
          STORAGE CONTROLLER = 3990
          STORAGE CONTROL DESCRIPTOR = EC
          DEVICE DESCRIPTOR = 0C
          ADDITIONAL DEVICE INFORMATION = 71002160
ICK04000I DEVICE IS IN SIMPLEX STATE
ICK00703I DEVICE IS OPERATED AS A MINIDISK
ICK03020I CPVOL WILL PROCESS 0200 FOR VM/ESA MODE
ICK03090I VOLUME SERIAL = LNX200
ICK03022I FORMATTING THE DEVICE WITHOUT FILLER RECORDS
ICK03011I CYLINDER RANGE TO BE FORMATTED IS 0 - 187
ICK003D REPLY U TO ALTER VOLUME 0200 CONTENTS, ELSE T
U
ICK03000I CPVOL REPORT FOR 0200 FOLLOWS:

          FORMATTING OF CYLINDER 0 STARTED AT: 11:33:05
          FORMATTING OF CYLINDER 100 ENDED AT: 11:33:18
          FORMATTING OF CYLINDER 187 ENDED AT: 11:33:29

          VOLUME SERIAL NUMBER IS NOW = LNX200

          CYLINDER ALLOCATION CURRENTLY IS AS FOLLOWS:
          TYPE     START     END     TOTAL
          ----     -----     ---     -----
          PERM     0         187     188

ICK00001I FUNCTION COMPLETED, HIGHEST CONDITION CODE WAS 0
          11:33:29    12/09/03

ENTER INPUT COMMAND:
 END

ICK00002I ICKDSF PROCESSING COMPLETE. MAXIMUM CONDITION CODE WAS 0
ENTER ALLOCATION DATA
TYPE CYLINDERS
....................
end
Ready; T=0.03/0.07 11:33:33

Cheers;

E!

-----------------
Eric Wilson
IBM Certified Advanced Technical Expert
RedHat Certified Engineer

Reply via email to