glen herrmannsfeldt wrote:

>In the olden days, the interval timer at address 80 could
>be updated with an MVC instruction.  The new value was
>stored at 84, and and 8 byte MVC move from 80 to 76 would
>update the timer and return the previous value without
>losing any counts.
>
>MVCL would not necessarily prevent the loss of counts.

I would suggest to consult the Principles of Operation, which has a whole
section (more than 10 pages) on exactly that topic:

5.13 Sequence of Storage References

and in particular

5.13.9 Storage Operand Consistency


Mit freundlichen Gruessen / Best Regards

Ulrich Weigand

--
  Dr. Ulrich Weigand
  Linux for S/390 Design & Development
  IBM Deutschland Entwicklung GmbH, Schoenaicher Str. 220, 71032 Boeblingen
  Phone: +49-7031/16-3727   ---   Email: [EMAIL PROTECTED]

Reply via email to