On Thursday, 10/14/2004 at 09:58 AST, "Peter E. Abresch Jr.   - at Pepco"
<[EMAIL PROTECTED]> wrote:
> Thanks for such a quick response. We are currently running HMC level
1.7.3.
> What exactly is the Integrated 3270 Console? Is it attached to a
controller
> or is it emulated somehow?

It is a machine service that allows 3270 data to flow between the LPAR and
a 3270 emulator built into the HMC, along the same lines as the integrated
linemode console (SYSC).  It is not a channel-attached device.

Alan Altmark
Sr. Software Engineer
IBM z/VM Development

----------------------------------------------------------------------