Make sure your initrd has the DIAG support module being loaded at IPL time. If you want to make your life a little easier, make sure to remove the FBA module. Then you won't need to play games with kernel parms, etc.
Mark Post -----Original Message----- From: Linux on 390 Port [mailto:[EMAIL PROTECTED] On Behalf Of John Kaba Sent: Monday, August 01, 2005 2:27 PM To: [email protected] Subject: Trouble setting DIAG on 3390 device(SuSE SLES 9) I have compiled DIAG in the kernel, and have modified ZIPL with the 'dasd=300,301(diag)' statement, and system would not boot. It gave me some message about not finding 301 or something like that. Anyway I took the 'dasd' statement out, and rebooted. I then try to manually switch dasd 301 offline, then set on diag with the 'echo 1 > /sys/bus/ccw/devices/0.0.0301 /use_diag' and then set back online. It then gives me the message "dasd_generic couldn't online device 0.0.0301 with discipline DIAG". What am I doing wrong? I was able to use DIAG with 300(VDISK), but have to set it manually. It always comes up with the FBA discipline. ---------------------------------------------------------------------- For LINUX-390 subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: INFO LINUX-390 or visit http://www.marist.edu/htbin/wlvindex?LINUX-390 ---------------------------------------------------------------------- For LINUX-390 subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: INFO LINUX-390 or visit http://www.marist.edu/htbin/wlvindex?LINUX-390