could someone please share their experience setting up snmpd.conf so
CPU/MEMORY/DISK information is made available via "/etc/init.d/snmpd"?

What I have done so far is set up the configuration file as follows:
# more /usr/local/share/snmp/snmpd.conf
syslocation Mainframe, Computer Room, SE 1st Floor
syscontact "[EMAIL PROTECTED]"
rocommunity public
disk /

I can see it is running after doing the /etc/init.d/snmpd start:
# ps aux | grep snmpd
root     18275  0.1  0.2  9828 5552 ?        S<   15:43   0:00 snmpd -a

However, I get the following:
# snmpget -v 1 -c const1payted localhost ifPhysAddress.2
Timeout: No Response from localhost.


I do get something when I do the following but I don't speak snmp:
# snmpwalk -v 1 -c public localhost interface
IF-MIB::ifNumber.0 = INTEGER: 4
IF-MIB::ifIndex.1 = INTEGER: 1
IF-MIB::ifIndex.2 = INTEGER: 2
IF-MIB::ifIndex.3 = INTEGER: 3
IF-MIB::ifIndex.4 = INTEGER: 4
IF-MIB::ifDescr.1 = STRING: lo
IF-MIB::ifDescr.2 = STRING: hsi0
IF-MIB::ifDescr.3 = STRING: eth0
IF-MIB::ifDescr.4 = STRING: sit0
IF-MIB::ifType.1 = INTEGER: softwareLoopback(24)
IF-MIB::ifType.2 = INTEGER: ethernetCsmacd(6)
IF-MIB::ifType.3 = INTEGER: ethernetCsmacd(6)
IF-MIB::ifType.4 = INTEGER: tunnel(131)
IF-MIB::ifMtu.1 = INTEGER: 16436
IF-MIB::ifMtu.2 = INTEGER: -32768
IF-MIB::ifMtu.3 = INTEGER: 1500
IF-MIB::ifMtu.4 = INTEGER: 1480
IF-MIB::ifSpeed.1 = Gauge32: 10000000
IF-MIB::ifSpeed.2 = Gauge32: 100000000
IF-MIB::ifSpeed.3 = Gauge32: 100000000
IF-MIB::ifSpeed.4 = Gauge32: 0
IF-MIB::ifPhysAddress.1 = STRING:
IF-MIB::ifPhysAddress.2 = STRING:
IF-MIB::ifPhysAddress.3 = STRING: 2:0:0:0:0:3
IF-MIB::ifPhysAddress.4 = STRING:
IF-MIB::ifAdminStatus.1 = INTEGER: up(1)
IF-MIB::ifAdminStatus.2 = INTEGER: up(1)
IF-MIB::ifAdminStatus.3 = INTEGER: up(1)
IF-MIB::ifAdminStatus.4 = INTEGER: down(2)
IF-MIB::ifOperStatus.1 = INTEGER: up(1)
IF-MIB::ifOperStatus.2 = INTEGER: up(1)
IF-MIB::ifOperStatus.3 = INTEGER: up(1)
IF-MIB::ifOperStatus.4 = INTEGER: down(2)
IF-MIB::ifInOctets.1 = Counter32: 17576626
IF-MIB::ifInOctets.2 = Counter32: 6333542
IF-MIB::ifInOctets.3 = Counter32: 898986645
IF-MIB::ifInOctets.4 = Counter32: 0
IF-MIB::ifInUcastPkts.1 = Counter32: 214432
IF-MIB::ifInUcastPkts.2 = Counter32: 54634
IF-MIB::ifInUcastPkts.3 = Counter32: 43633870
IF-MIB::ifInUcastPkts.4 = Counter32: 0
IF-MIB::ifInDiscards.1 = Counter32: 0
IF-MIB::ifInDiscards.2 = Counter32: 0
IF-MIB::ifInDiscards.3 = Counter32: 0
IF-MIB::ifInDiscards.4 = Counter32: 0
IF-MIB::ifInErrors.1 = Counter32: 0
IF-MIB::ifInErrors.2 = Counter32: 0
IF-MIB::ifInErrors.3 = Counter32: 0
IF-MIB::ifInErrors.4 = Counter32: 0
IF-MIB::ifOutOctets.1 = Counter32: 17576626
IF-MIB::ifOutOctets.2 = Counter32: 4344
IF-MIB::ifOutOctets.3 = Counter32: 1671863673
IF-MIB::ifOutOctets.4 = Counter32: 0
IF-MIB::ifOutUcastPkts.1 = Counter32: 214432
IF-MIB::ifOutUcastPkts.2 = Counter32: 27
IF-MIB::ifOutUcastPkts.3 = Counter32: 9459278
IF-MIB::ifOutUcastPkts.4 = Counter32: 0
IF-MIB::ifOutDiscards.1 = Counter32: 0
IF-MIB::ifOutDiscards.2 = Counter32: 0
IF-MIB::ifOutDiscards.3 = Counter32: 0
IF-MIB::ifOutDiscards.4 = Counter32: 0
IF-MIB::ifOutErrors.1 = Counter32: 0
IF-MIB::ifOutErrors.2 = Counter32: 0
IF-MIB::ifOutErrors.3 = Counter32: 0
IF-MIB::ifOutErrors.4 = Counter32: 0
IF-MIB::ifOutQLen.1 = Gauge32: 0
IF-MIB::ifOutQLen.2 = Gauge32: 0
IF-MIB::ifOutQLen.3 = Gauge32: 0
IF-MIB::ifOutQLen.4 = Gauge32: 0
IF-MIB::ifSpecific.1 = OID: SNMPv2-SMI::zeroDotZero
IF-MIB::ifSpecific.2 = OID: SNMPv2-SMI::zeroDotZero
IF-MIB::ifSpecific.3 = OID: SNMPv2-SMI::zeroDotZero
IF-MIB::ifSpecific.4 = OID: SNMPv2-SMI::zeroDotZero


When I go to another host and issue:
snmpget -c public 172.xx.xx.xx  (the place where snmpd is running)
system.sysDescr.0
I get:
snmpget: Timeout (Sub-ID not found: iso -> system)

----------------------------------------------------------------------