could someone please share their experience setting up snmpd.conf so CPU/MEMORY/DISK information is made available via "/etc/init.d/snmpd"?
What I have done so far is set up the configuration file as follows: # more /usr/local/share/snmp/snmpd.conf syslocation Mainframe, Computer Room, SE 1st Floor syscontact "[EMAIL PROTECTED]" rocommunity public disk / I can see it is running after doing the /etc/init.d/snmpd start: # ps aux | grep snmpd root 18275 0.1 0.2 9828 5552 ? S< 15:43 0:00 snmpd -a However, I get the following: # snmpget -v 1 -c const1payted localhost ifPhysAddress.2 Timeout: No Response from localhost. I do get something when I do the following but I don't speak snmp: # snmpwalk -v 1 -c public localhost interface IF-MIB::ifNumber.0 = INTEGER: 4 IF-MIB::ifIndex.1 = INTEGER: 1 IF-MIB::ifIndex.2 = INTEGER: 2 IF-MIB::ifIndex.3 = INTEGER: 3 IF-MIB::ifIndex.4 = INTEGER: 4 IF-MIB::ifDescr.1 = STRING: lo IF-MIB::ifDescr.2 = STRING: hsi0 IF-MIB::ifDescr.3 = STRING: eth0 IF-MIB::ifDescr.4 = STRING: sit0 IF-MIB::ifType.1 = INTEGER: softwareLoopback(24) IF-MIB::ifType.2 = INTEGER: ethernetCsmacd(6) IF-MIB::ifType.3 = INTEGER: ethernetCsmacd(6) IF-MIB::ifType.4 = INTEGER: tunnel(131) IF-MIB::ifMtu.1 = INTEGER: 16436 IF-MIB::ifMtu.2 = INTEGER: -32768 IF-MIB::ifMtu.3 = INTEGER: 1500 IF-MIB::ifMtu.4 = INTEGER: 1480 IF-MIB::ifSpeed.1 = Gauge32: 10000000 IF-MIB::ifSpeed.2 = Gauge32: 100000000 IF-MIB::ifSpeed.3 = Gauge32: 100000000 IF-MIB::ifSpeed.4 = Gauge32: 0 IF-MIB::ifPhysAddress.1 = STRING: IF-MIB::ifPhysAddress.2 = STRING: IF-MIB::ifPhysAddress.3 = STRING: 2:0:0:0:0:3 IF-MIB::ifPhysAddress.4 = STRING: IF-MIB::ifAdminStatus.1 = INTEGER: up(1) IF-MIB::ifAdminStatus.2 = INTEGER: up(1) IF-MIB::ifAdminStatus.3 = INTEGER: up(1) IF-MIB::ifAdminStatus.4 = INTEGER: down(2) IF-MIB::ifOperStatus.1 = INTEGER: up(1) IF-MIB::ifOperStatus.2 = INTEGER: up(1) IF-MIB::ifOperStatus.3 = INTEGER: up(1) IF-MIB::ifOperStatus.4 = INTEGER: down(2) IF-MIB::ifInOctets.1 = Counter32: 17576626 IF-MIB::ifInOctets.2 = Counter32: 6333542 IF-MIB::ifInOctets.3 = Counter32: 898986645 IF-MIB::ifInOctets.4 = Counter32: 0 IF-MIB::ifInUcastPkts.1 = Counter32: 214432 IF-MIB::ifInUcastPkts.2 = Counter32: 54634 IF-MIB::ifInUcastPkts.3 = Counter32: 43633870 IF-MIB::ifInUcastPkts.4 = Counter32: 0 IF-MIB::ifInDiscards.1 = Counter32: 0 IF-MIB::ifInDiscards.2 = Counter32: 0 IF-MIB::ifInDiscards.3 = Counter32: 0 IF-MIB::ifInDiscards.4 = Counter32: 0 IF-MIB::ifInErrors.1 = Counter32: 0 IF-MIB::ifInErrors.2 = Counter32: 0 IF-MIB::ifInErrors.3 = Counter32: 0 IF-MIB::ifInErrors.4 = Counter32: 0 IF-MIB::ifOutOctets.1 = Counter32: 17576626 IF-MIB::ifOutOctets.2 = Counter32: 4344 IF-MIB::ifOutOctets.3 = Counter32: 1671863673 IF-MIB::ifOutOctets.4 = Counter32: 0 IF-MIB::ifOutUcastPkts.1 = Counter32: 214432 IF-MIB::ifOutUcastPkts.2 = Counter32: 27 IF-MIB::ifOutUcastPkts.3 = Counter32: 9459278 IF-MIB::ifOutUcastPkts.4 = Counter32: 0 IF-MIB::ifOutDiscards.1 = Counter32: 0 IF-MIB::ifOutDiscards.2 = Counter32: 0 IF-MIB::ifOutDiscards.3 = Counter32: 0 IF-MIB::ifOutDiscards.4 = Counter32: 0 IF-MIB::ifOutErrors.1 = Counter32: 0 IF-MIB::ifOutErrors.2 = Counter32: 0 IF-MIB::ifOutErrors.3 = Counter32: 0 IF-MIB::ifOutErrors.4 = Counter32: 0 IF-MIB::ifOutQLen.1 = Gauge32: 0 IF-MIB::ifOutQLen.2 = Gauge32: 0 IF-MIB::ifOutQLen.3 = Gauge32: 0 IF-MIB::ifOutQLen.4 = Gauge32: 0 IF-MIB::ifSpecific.1 = OID: SNMPv2-SMI::zeroDotZero IF-MIB::ifSpecific.2 = OID: SNMPv2-SMI::zeroDotZero IF-MIB::ifSpecific.3 = OID: SNMPv2-SMI::zeroDotZero IF-MIB::ifSpecific.4 = OID: SNMPv2-SMI::zeroDotZero When I go to another host and issue: snmpget -c public 172.xx.xx.xx (the place where snmpd is running) system.sysDescr.0 I get: snmpget: Timeout (Sub-ID not found: iso -> system) ---------------------------------------------------------------------- For LINUX-390 subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: INFO LINUX-390 or visit http://www.marist.edu/htbin/wlvindex?LINUX-390