FYI, an apar has been opened (below) and a workaround is presented for an
XRC suspend that occurs when formatting a VM minidisk.
Mary Anne
APAR= OA26125 SER= MS MSGANTX5104E
XRC ANTX5104E RC=0901 DURING FORMAT OF A VM MINIDISK
STAT= OPEN FESN0565517- CTID= TU0260 ISEV= 2
SB08/08/13 RC08/08/14 CL PD SEV= 2
PE= TYPE= F
RCOMP= 5695DF117 SYSTEM DATA MOV RREL= R1K0
FCOMP= PFREL= F TREL= T
ACTION= SEC/INT= N DUP/
USPTF= PDPTF= DUPS 0
ERROR DESCRIPTION:
ANTX5104E RC=0901 occurs while formatting a VM minidisk that is
a primary in a XRC session, where XRC parameter PavVolumes is
greater than 1.
KEYWORDS:
ANTX5104E RC=0901 NRFITF NRF NO RECORD FOUND ITF INVALID TRACK
FORMAT MSGANTX5104E RC=901 RC0901 RC901
LOCAL FIX:
1. Change the PavVolumes parameter to 1 in the XRC parmlib
member for future sessions, and use the XSET command to
change the value of PavVolumes to 1 for the current sessions.
- or -
2. Remove the pair from the XRC session before performing a
format, then readd the pair after the format is complete.
(recommended)
----------------------------------------------------------------------