>The 6500s have a feature called "Virtual Switching System (VSS) 1440" that
>allows multiple switches to appear as one.  (Btw, IEEE 802.3ad requires
>awareness of what's going on on all the links.  This isn't a limitation of
>the VSWITCH.)

We operate in that way and found a major drawback: The physical switches 
operate on the same-box principle, meaning what comes in on one box is sent out 
over LA members on that box. There is no attempt at load balancing by 
forwarding over the ISL to the other box and out to LA members on that other 
box. We ended up with three links on one box and the fourth as failover on the 
other box.