>Isn't there (wasn't there?) a statement from IBM saying that direct
>connect of FCP to storage (i.e., a DS8000 or EMC DMX) is supported "for
>demonstration purposes only" -- or something like that?
>
>I thought I read somewhere that only fabric was supported for production
>work.   But now can't lay my hands (aka: web browser) on that doc...
>Lee
>--
>
>Lee Stewart, Senior SE
>Sirius Computer Solutions
>Phone: (303) 996-7122
>Email: [email protected]
>Web:   www.siriuscom.com

Lee,
Your correct, there "was" a statement saying that point to point was only
supported/recommended for development/test environments. That has changed
somewhat now.  Point-to-Point is supported on z9 or later and requires
RHEL4U7, RHEL5, SLES9SP4, SLES10, SLES11. On qualified devices only, not
all devices have been tested in a point to point configuration and are
therefore not supported. There is no NPIV support with a Point-to-Point
configuration.
Ref SG24-5444-10, pg53, IBM System z Connectivity Handbook.

John
----------------------------------------------------------------------
For LINUX-390 subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO LINUX-390 or visit
http://www.marist.edu/htbin/wlvindex?LINUX-390