If you are putting in a z14 and are running Connect:Direct under Linux you
need to get a yet unreleased fixpack or all of your secure+ will fail.


Spectrum Scale also requires 4.2.3.6 and WAS IHS requires 8.5.5.13.

Anything that uses GSKIT needs examination.  MQ and DB2 also use it.  We
haven’t seen problems there but we also are very current on all software
these days.


-- 
Marcy

----------------------------------------------------------------------
For LINUX-390 subscribe / signoff / archive access instructions,
send email to lists...@vm.marist.edu with the message: INFO LINUX-390 or visit
http://www.marist.edu/htbin/wlvindex?LINUX-390
----------------------------------------------------------------------
For more information on Linux on System z, visit
http://wiki.linuxvm.org/