Oh, and if this is a reference to running 2nd level with SCSI, then you simply ATTACH/DEDICATE the FCP subchannels from the 1st level system to your 2nd level guest. They can be attached with virtual addresses that match your configuration at home, but your 2nd level system and its guests still must be configured to work with the DR storage configuration.
Regards, Alan Alan Altmark Senior Managing z/VM Consultant IBM Technology Services 1 607 321 7556 (Mobile) [email protected] > -----Original Message----- > From: Linux on 390 Port <[email protected]> On Behalf Of Peter > Sent: Tuesday, June 28, 2022 5:04 AM > To: [email protected] > Subject: [EXTERNAL] [LINUX-390] FCP device > > Hello > > Good morning > > How do we create WWPN or FBA device in DR site ? > > As this is the first time we are planning to replicate Linux guest to DR site. > > Is there a way to assign or attach a FBA device to the Linux guest ? > > Peter ---------------------------------------------------------------------- For LINUX-390 subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO LINUX-390 or visit http://www2.marist.edu/htbin/wlvindex?LINUX-390
