On Fri, Feb 16, 2001 at 01:52:01PM +0100, Bogdan Costescu wrote: > On Thu, 15 Feb 2001, William Park wrote: > > > This is not related to Beowulf specifically. But, I'm trying to put > > together 8-cpu Linux cluster, and need some basic insight to ethernet > > card problem. > > Probably the best would have been [EMAIL PROTECTED], but I'll answer here. > > > I have 2 VP6 machines with 3c905 ethernet card (3c905B in one, > > 3c905C in the other). Each machine can ping itself, but not each > > other. I think packet is going out, since LED on ethernet switch > > (5-port SmartLink) is blinking. > > Can you check the inscription on your 3C905C card(s) (by opening the case) > to see if they are 3C905CX (notice the X at the end) ? The CX cards are > newly introduced by 3Com and have a small change in design: they need more > time to reset their Rx part. This is only added to the recent drivers. > If the Rx reset is not done properly, the card will not receive any > packet, so the described behaviour is to be expected. Hi Bogdan, Thanks for the pointers. Indeed, my cards are - 3c905B-TXM and 3c905CX-TXM Fortunately, I was able to find '3c90x' module from 3Com website, and it works with the new 3c905CX. I am using it as module, right now. Later, I'll compile it into kernel. ---William Park, Open Geometry Consulting -- =- To unsubscribe, email [EMAIL PROTECTED] with the -= =- body of "unsubscribe linux-abit". -=