Even in cases where the consumer driver calls the regulator core with
different voltage min/max values, the application of the various
voltage constraints could result in the min/max voltage values passed
to the regulator driver to be unchanged since the previous invocation.

Optimize these cases by not calling into the regulator driver and not
sending incorrect/unnecessary voltage change notifications.

Signed-off-by: Saravana Kannan <[email protected]>
---
 drivers/regulator/core.c |   10 ++++++++--
 1 files changed, 8 insertions(+), 2 deletions(-)

diff --git a/drivers/regulator/core.c b/drivers/regulator/core.c
index ba521f0..c2e67bb 100644
--- a/drivers/regulator/core.c
+++ b/drivers/regulator/core.c
@@ -1640,12 +1640,18 @@ int regulator_set_voltage(struct regulator *regulator, 
int min_uV, int max_uV)
        ret = regulator_check_voltage(rdev, &min_uV, &max_uV);
        if (ret < 0)
                goto out;
-       regulator->min_uV = min_uV;
-       regulator->max_uV = max_uV;
+
+       if (regulator->min_uV == min_uV && regulator->max_uV == max_uV)
+               goto unlock;
        ret = rdev->desc->ops->set_voltage(rdev, min_uV, max_uV);
+       if (!ret) {
+               regulator->min_uV = min_uV;
+               regulator->max_uV = max_uV;
+       }
 
 out:
        _notifier_call_chain(rdev, REGULATOR_EVENT_VOLTAGE_CHANGE, NULL);
+unlock:
        mutex_unlock(&rdev->mutex);
        return ret;
 }
-- 
1.7.1.1
--
Sent by an employee of the Qualcomm Innovation Center, Inc.
The Qualcomm Innovation Center, Inc. is a member of the Code Aurora Forum.
--
To unsubscribe from this list: send the line "unsubscribe linux-arm-msm" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html

Reply via email to