On 2017/7/1 上午4:42, [email protected] wrote:
> From: Tang Junhui <[email protected]>
> 
> Since bypassed IOs use no bucket, so do not subtract sectors_to_gc to
> trigger gc thread.
> 
> Signed-off-by: tang.junhui <[email protected]>
> Reviewed-by: Eric Wheeler <[email protected]>
> Cc: [email protected]

Acked-by: Coly Li <[email protected]>

Thanks.

> ---
>  drivers/md/bcache/request.c | 6 +++---
>  1 file changed, 3 insertions(+), 3 deletions(-)
> 
> diff --git a/drivers/md/bcache/request.c b/drivers/md/bcache/request.c
> index 958072a..4b413db 100644
> --- a/drivers/md/bcache/request.c
> +++ b/drivers/md/bcache/request.c
> @@ -196,12 +196,12 @@ static void bch_data_insert_start(struct closure *cl)
>       struct data_insert_op *op = container_of(cl, struct data_insert_op, cl);
>       struct bio *bio = op->bio, *n;
>  
> -     if (atomic_sub_return(bio_sectors(bio), &op->c->sectors_to_gc) < 0)
> -             wake_up_gc(op->c);
> -
>       if (op->bypass)
>               return bch_data_invalidate(cl);
>  
> +     if (atomic_sub_return(bio_sectors(bio), &op->c->sectors_to_gc) < 0)
> +             wake_up_gc(op->c);
> +
>       /*
>        * Journal writes are marked REQ_PREFLUSH; if the original write was a
>        * flush, it'll wait on the journal write.
> 


-- 
Coly Li