Desculpe a ignorância, mas "Hardware_ECC_Recovered" está relacionado a temperatura??? Outra coisa seria "Raw_Read_Error_Rate", não acho estar relacionado com temperatura, concorda?!
Para não ter mais confusões, tanto no HDA quanto no HDB, seriam estes os logs preocupantes: Sep 21 10:01:54 servidor smartd[3346]: Device: /dev/hda, SMART Prefailure Attribute: 1 Raw_Read_Error_Rate changed from 62 to 61 Sep 21 10:01:54 servidor smartd[3346]: Device: /dev/hda, SMART Usage Attribute: 195 Hardware_ECC_Recovered changed from 62 to 61 Sep 21 10:31:55 servidor smartd[3346]: Device: /dev/hdb, SMART Prefailure Attribute: 1 Raw_Read_Error_Rate changed from 66 to 65 Sep 21 10:31:55 servidor smartd[3346]: Device: /dev/hdb, SMART Usage Attribute: 195 Hardware_ECC_Recovered changed from 66 to 65 Sds, -- Leonardo Pinto listas#openlogic dot com br Citando "[EMAIL PROTECTED]" <[EMAIL PROTECTED]>: > > Acredito que, o fato de um hd mais antigo nao ter reportado mensagens de > variações de temperatura pode ser devido ao fato de simplesmente o hd > antigo nao ter essa informacao disponivel no smart.. > > Quanto a variação de temperatura sendo reportada nos hds mais novos, > pode ser considerada normal, desde que nao ultrapasse os valores maximo > e minimo do fabricante.. > > Em Qui, 2006-09-21 às 09:57 -0400, Leonardo Pinto escreveu: >> Iniciei uma implantação em série do SmartMonTools em todos os "nossos" >> servidores. Porém num servidor que tem seus HDs substituídos recentemente, >> encontrei este aviso do Smart. E o estranho é que num servidor com o HD >> funcionando a mais de 4 anos não foi reportado nenhum aviso. >> >> (...) >> Sep 21 09:31:54 servidor smartd: smartd startup succeeded >> Sep 21 10:01:54 servidor smartd[3346]: Device: /dev/hda, SMART >> Prefailure Attribute: 1 Raw_Read_Error_Rate changed from 62 to 61 >> Sep 21 10:01:54 servidor smartd[3346]: Device: /dev/hda, SMART Usage >> Attribute: 195 Hardware_ECC_Recovered changed from 62 to 61 >> Sep 21 10:31:54 servidor smartd[3346]: Device: /dev/hda, SMART Usage >> Attribute: 194 Temperature_Celsius changed from 47 to 50 >> Sep 21 10:31:55 servidor smartd[3346]: Device: /dev/hdb, SMART >> Prefailure Attribute: 1 Raw_Read_Error_Rate changed from 66 to 65 >> Sep 21 10:31:55 servidor smartd[3346]: Device: /dev/hdb, SMART Usage >> Attribute: 194 Temperature_Celsius changed from 48 to 51 >> Sep 21 10:31:55 servidor smartd[3346]: Device: /dev/hdb, SMART Usage >> Attribute: 195 Hardware_ECC_Recovered changed from 66 to 65 >> >> Sds, >> >> -- >> Leonardo Pinto >> listas#openlogic dot com br ------------------------------------------------------------------ Esta e' uma mensagem enviada usando o OpenLogic OwbMail Messaging. --------------------------------------------------------------------------- Esta lista é patrocinada pela Conectiva S.A. Visite http://www.conectiva.com.br Arquivo: http://bazar2.conectiva.com.br/mailman/listinfo/linux-br Regras de utilização da lista: http://linux-br.conectiva.com.br FAQ: http://www.zago.eti.br/menu.html