Desculpe a ignorância, mas "Hardware_ECC_Recovered" está relacionado a
temperatura???
Outra coisa seria "Raw_Read_Error_Rate", não acho estar relacionado com
temperatura, concorda?!

Para não ter mais confusões, tanto no HDA quanto no HDB, seriam estes os logs
preocupantes:

Sep 21 10:01:54 servidor smartd[3346]: Device: /dev/hda, SMART
Prefailure Attribute: 1 Raw_Read_Error_Rate changed from 62 to 61
Sep 21 10:01:54 servidor smartd[3346]: Device: /dev/hda, SMART Usage
Attribute: 195 Hardware_ECC_Recovered changed from 62 to 61

Sep 21 10:31:55 servidor smartd[3346]: Device: /dev/hdb, SMART
Prefailure Attribute: 1 Raw_Read_Error_Rate changed from 66 to 65
Sep 21 10:31:55 servidor smartd[3346]: Device: /dev/hdb, SMART Usage
Attribute: 195 Hardware_ECC_Recovered changed from 66 to 65

Sds,

--
Leonardo Pinto
listas#openlogic dot com br


Citando "[EMAIL PROTECTED]" <[EMAIL PROTECTED]>:

>
> Acredito que, o fato de um hd mais antigo nao ter reportado mensagens de
> variações de temperatura pode ser devido ao fato de simplesmente o hd
> antigo nao ter essa informacao disponivel no smart..
>
> Quanto a variação de temperatura sendo reportada nos hds mais novos,
> pode ser considerada normal, desde que nao ultrapasse os valores maximo
> e minimo do fabricante..
>
> Em Qui, 2006-09-21 às 09:57 -0400, Leonardo Pinto escreveu:
>> Iniciei uma implantação em série do SmartMonTools em todos os "nossos"
>> servidores. Porém num servidor que tem seus HDs substituídos recentemente,
>> encontrei este aviso do Smart. E o estranho é que num servidor com o HD
>> funcionando a mais de 4 anos não foi reportado nenhum aviso.
>>
>> (...)
>> Sep 21 09:31:54 servidor smartd: smartd startup succeeded
>> Sep 21 10:01:54 servidor smartd[3346]: Device: /dev/hda, SMART
>> Prefailure Attribute: 1 Raw_Read_Error_Rate changed from 62 to 61
>> Sep 21 10:01:54 servidor smartd[3346]: Device: /dev/hda, SMART Usage
>> Attribute: 195 Hardware_ECC_Recovered changed from 62 to 61
>> Sep 21 10:31:54 servidor smartd[3346]: Device: /dev/hda, SMART Usage
>> Attribute: 194 Temperature_Celsius changed from 47 to 50
>> Sep 21 10:31:55 servidor smartd[3346]: Device: /dev/hdb, SMART
>> Prefailure Attribute: 1 Raw_Read_Error_Rate changed from 66 to 65
>> Sep 21 10:31:55 servidor smartd[3346]: Device: /dev/hdb, SMART Usage
>> Attribute: 194 Temperature_Celsius changed from 48 to 51
>> Sep 21 10:31:55 servidor smartd[3346]: Device: /dev/hdb, SMART Usage
>> Attribute: 195 Hardware_ECC_Recovered changed from 66 to 65
>>
>> Sds,
>>
>> --
>> Leonardo Pinto
>> listas#openlogic dot com br


------------------------------------------------------------------
Esta e' uma mensagem enviada usando o OpenLogic OwbMail Messaging.

---------------------------------------------------------------------------
Esta lista é patrocinada pela Conectiva S.A. Visite http://www.conectiva.com.br

Arquivo: http://bazar2.conectiva.com.br/mailman/listinfo/linux-br
Regras de utilização da lista: http://linux-br.conectiva.com.br
FAQ: http://www.zago.eti.br/menu.html

Responder a