Bom dia !
Segue as informações:

Modelo máquina: HP Proliant ML 150 G3
Modelo placa de rede: Placa de Rede On-board HP NC7781 Gigabit Server  
Adapter 10/100/1000 WOL
Máquina nova: Compramos em Julho/2007

Drivers placa de rede:
ethtool -i eth0
driver: tg3
version: 3.59.1
firmware-version: 5703-v2.35
bus-info: 0000:07:01.0

lsmod | grep tg3
tg3                   102020  0

more /etc/modprobe.conf | grep tg3
alias eth0 tg3

lspci -v
07:01.0 Ethernet controller: Broadcom Corporation NetXtreme BCM5703X  
Gigabit Ethernet (rev 02)
         Subsystem: Compaq Computer Corporation NC7781 Gigabit Server  
Adapter (PCI-X, 10,100,1000-T)
         Flags: bus master, 66MHz, medium devsel, latency 64, IRQ 17
         Memory at df800000 (64-bit, non-prefetchable) [size=64K]
         [virtual] Expansion ROM at df820000 [disabled] [size=64K]
         Capabilities: [40] PCI-X non-bridge device
         Capabilities: [48] Power Management version 2
         Capabilities: [50] Vital Product Data
         Capabilities: [58] Message Signalled Interrupts: 64bit+  
Queue=0/3 Enable-

more cabo_desconectado.txt
Settings for eth0:
         Supported ports: [ MII ]
         Supported link modes:   10baseT/Half 10baseT/Full
                                 100baseT/Half 100baseT/Full
                                 1000baseT/Half 1000baseT/Full
         Supports auto-negotiation: Yes
         Advertised link modes:  Not reported
         Advertised auto-negotiation: No
         Speed: 100Mb/s
         Duplex: Full
         Port: Twisted Pair
         PHYAD: 1
         Transceiver: internal
         Auto-negotiation: off
         Supports Wake-on: g
         Wake-on: d
         Current message level: 0x000000ff (255)
         Link detected: no

more cabo_conectado.txt
Settings for eth0:
         Supported ports: [ MII ]
         Supported link modes:   10baseT/Half 10baseT/Full
                                 100baseT/Half 100baseT/Full
                                 1000baseT/Half 1000baseT/Full
         Supports auto-negotiation: Yes
         Advertised link modes:  Not reported
         Advertised auto-negotiation: No
         Speed: 100Mb/s
         Duplex: Full
         Port: Twisted Pair
         PHYAD: 1
         Transceiver: internal
         Auto-negotiation: off
         Supports Wake-on: g
         Wake-on: d
         Current message level: 0x000000ff (255)
         Link detected: yes

dmesg | grep eth
tg3: eth0: Link is up at 100 Mbps, full duplex.
tg3: eth0: Flow control is on for TX and on for RX.

Muito obrigado.
Abraços.
JBrasil.

Citando "Juliano F. Ravasi" <[EMAIL PROTECTED]>:

> [EMAIL PROTECTED] wrote:
>> Veja o erro, ao executar o comando abaixo:
>>
>> ethtool -s eth0 speed 1000 duplex full autoneg off
>> Cannot set new settings: Invalid argument
>>    not setting speed
>>    not setting duplex
>>    not setting autoneg
>
> Estranho. Pela experiência que eu tenho, as placas Gigabit funcionam por
> padrão na velocidade mais alta que conseguem, sem precisar usar ethtool.
> Eu não desligaria a auto-negociação.
>
> Você não passou o modelo da placa. Seria bom saber o que o lspci -v diz
> e se aparece alguma mensagem relevante no dmesg.
>
> Isso aqui:
>
>>          Advertised link modes:  Not reported
>>          Advertised auto-negotiation: No
>
> Não deveria ser. Pode ser porque você forneceu "autoneg off" acima.
> Remova todos os comandos ethtool (inclusive aquele no ifcfg-eth0),
> reinicie e poste novamente o resultado do ethtool, primeiro com o cabo
> desconectado, depois com ele conectado.
>
>
> --
> Juliano F. Ravasi ·· http://juliano.info/
> 5105 46CC B2B7 F0CD 5F47 E740 72CA 54F4 DF37 9E96
>
> "A candle loses nothing by lighting another candle." -- Erin Majors
>
> * NOTE: Don't try to reach me through this address, use "contact@" instead.
>


---------------------------------------------------------------------------
Esta lista é patrocinada pela Conectiva S.A. Visite http://www.conectiva.com.br

Arquivo: http://bazar2.conectiva.com.br/mailman/listinfo/linux-br
Regras de utilização da lista: http://linux-br.conectiva.com.br
FAQ: http://www.zago.eti.br/menu.html

Responder a